Ashly PE-Series manual Troubleshooting, Situation, Indication, Action, Page, All Rights Reserved

Models: PE-Series

1 13
Download 13 pages 23.22 Kb
Page 9
Image 9
Troubleshooting

Operator Manual – PE Series Amplifiers

Page - 9

Troubleshooting

Situation

Indication

Action

No Sound

Signal LED not lit

Check AC plug. Confirm that AC outlet works by plugging

 

Clip LEDs not lit

in another device.

 

 

 

 

Output Current LEDs are lit

Make sure the signal source is operating and try another

 

Signal LED not lit

cable. Check position of Volume Pots.

 

 

 

 

Output Current LEDs are lit

Check the speaker wiring for breaks.

 

Signal LEDs responding to signal level

Try another speaker and cable.

 

Signal LEDs show red (Protect Mode)

Overheating will cause protective muting. Check for

 

 

proper ventilation. If the fan isn’t running the amplifier

 

 

requires servicing.

No Channel

No Channel Separation

Check the mode indicators on the front panel and make

Separation

 

sure the mode selector on the rear panel is in the stereo-

 

 

position. Make sure other equipment in the signal path

 

 

such as mixers and preamps are set for stereo, not mono

Distorted Sound

Power LED is lit

A faulty speaker or a loose connection could cause this.

 

 

Check the wiring and try another speaker.

 

Signal LEDs responding to signal level

The signal source might be clipping. Keep the volume

 

 

pots at least halfway up so that the source does not have

 

 

to be overdriven.

 

Clip LEDs not lit

Keep the volume pots at least halfway up and try

 

 

changing input sensitivity from 1,4 V to 32 dB or 26 dB

 

 

with the gain selector on the rear.

Hiss

Hiss

Unplug the amplifier input to confirm that the hiss is

 

 

coming from the source or from a device upstream. Erratic

 

 

or popping noises indicate an electronic fault in the

 

 

offending unit. To keep the noise floor low, operate the

 

 

primary signal source at full level, without clipping. Avoid

 

 

boosting the signal further between the source and the

 

 

amplifier.

Squeals and

Squeals and Feedback

Microphone feedback should be eliminated with mixer

Feedback

 

controls. If noise continues to build up with no microphone

 

 

gain, there is a serious fault in the signal processors or

 

 

cables. Working in succession from the signal source

 

 

towards the amplifier and check each device in the signal

 

 

path by reducing its gain or by unplugging it.

Protea

Comm LED lit

Check connection between computer and any routers or

Communications

 

switched in the network. Reboot computer. If issue is not

Failure

 

resolved, consider replacing CAT-5 Cables

 

Comm LED not lit

Check connection between amplifier and network. Reboot

 

 

computer. If issue is not resolved, consider replacing

 

 

CAT-5 Cables

Important Safety

Instructions – 2

Introduction - 3

The PE Series - 4

Physical Description - 5

Installation – 6

Operation – 8

Troubleshooting - 9

Spec Table - 10

Measurements - 11

Dimensions - 12

Warranty - 13

All Rights Reserved

Rev 3.1 0506

Page 9
Image 9
Ashly PE-Series Troubleshooting, Situation, Indication, Action, Operator Manual - PE Series Amplifiers, Page, Warranty