Specifications

 

 

 

 

 

 

 

Safety Instructions – 3

 

 

 

 

 

 

Introduction – 4

 

Specification

XR 1001

XR 2001

XR 4001

 

 

 

 

 

Input Level Control

-to +8.5 dB

-to +8.5 dB

-to +8.5 dB

 

XR Crossovers – 5

 

Damping/Response

2dB – 12dB

2dB – 12dB

2dB – 12dB

 

Connectors & Cables–5

 

Output Level Control

-to +15 dB

-to +15 dB

-to +15 dB

 

Physical Description – 6

 

Input Impedance

20K Balanced

20K Balanced

20K Balanced

 

 

 

 

 

 

Output Impedance

100 Servo Balanced

100 Servo Balanced

100 Servo Balanced

 

Installation – 7

 

Maximum Input Level

+23 dBu

+23 dBu

+23 dBu

 

Typical Applications – 8

 

Maximum Output Level

+23 dBu

+23 dBu

+23 dBu

 

Troubleshooting - 10

 

Frequency Response

±0.5dB 20Hz-20kHz

±0.5dB 20Hz-20kHz

±0.5dB 20Hz-20kHz

 

 

 

Dimensions - 10

 

 

<0.05% THD (+10 dBu 20 Hz-

<0.05% THD (+10 dBu 20 Hz-

<0.05% THD (+10 dBu 20 Hz-

 

 

Distortion

20kHz)

20kHz)

20kHz)

 

Specifications - 11

 

Slew Rate

6V/μS

6V/μS

6V/μS

 

Warranty - 12

 

Hum and Noise

<-95dBu unweighted 20 Hz-20kHz

<-95dBu unweighted 20 Hz-20kHz

<-95dBu unweighted 20 Hz-20kHz

 

 

 

 

 

 

 

100-240 VAC 50-60 Hz

100-240 VAC 50-60 Hz

100-240 VAC 50-60 Hz

 

 

 

 

Power Requirements

24 Watts

24 Watts

24 Watts

 

 

 

 

Shipping Weight

13 lbs

16 lbs

16 lbs

 

 

 

 

Dimensions

19”Lx1.75”Hx8”D

19”Lx3.5”Hx8”D

19”Lx3.5”Hx8”D

 

 

 

 

 

 

 

 

 

 

 

All Rights Reserved

Page 11
Image 11
Ashly XR-4001 manual Specifications, Operator Manual -XRSeries Crossovers, Page, All Rights Reserved, Safety Instructions