Ashly XR-1001, XR-2001 Troubleshooting, Dimensions, Situation, Action, Page, Typical Applications

Models: XR-4001 XR-1001 XR-2001

1 13
Download 13 pages 13.63 Kb
Page 10
Image 10
Typical Applications – 8

Page - 10

Operator Manual – XR Series Crossovers

 

 

 

Safety Instructions – 3

Introduction – 4

XR Crossovers – 5

Connectors & Cables–5

Physical Description – 6

Installation – 7

Typical Applications – 8

Troubleshooting - 10

Dimensions - 10

Specifications - 11

Warranty - 12

Troubleshooting

Situation

Action

No Output

Check AC power - is LED indicator on? Check in/out connections, are they reversed? Are

 

you sure you have input signal?

 

 

Peak light flashes

The level is too high somewhere in the crossover. Try turning down individual output levels

frequently

and then the input until the peak LED stays off. If the peak LED continues to flash when all of

 

the crossover level controls are turned down, then the crossover is being fed excessively

 

high levels from a previous piece of equipment. Turn down your driving source.

Distorted sound

Is the peak light flashing? If it is, an overload is occurring within the crossover, and may also

 

be occurring in other parts of the system. If the peak light is not flashing, the distortion is

 

occurring somewhere outside the crossover.

Excessive hum or noise

Hum will usually be caused by a “ground loop” between components. Try using the

 

suggested balanced input and output hookups if the other pieces of equipment used in

 

conjunction with your crossover have balanced inputs and outputs. Noise can be caused by

 

insufficient drive signal. Ashly crossovers provide the best noise and headroom performance

 

when the input signal is 0 to +4dBu level and power amplifier sensitivity is higher than 1 volt.

 

Unshielded cables, improperly wired connections, and cable with broken strands (shorts,

 

etc.) are the most common problems. Please properly maintain and inspect your wiring first.

Note: Unshielded cables, improperly wired connections, and cable with broken strands (shorts, etc.) are the most common problems. Make sure you use good quality cable with connectors soldered firmly on the correct pin. When in doubt, get in touch with your Ashly dealer.

Dimensions

Copyright© 2006 – Ashly Audio Inc.

Page 10
Image 10
Ashly XR-1001, XR-2001 manual Troubleshooting, Dimensions, Situation, Action, Page, Operator Manual - XR Series Crossovers