This troubleshooting guide provides answers to some common problems that you may encounter while installing and/or using ASUS
Problem
The local/central server cannot connect to the
The ARC cannot receive PET information from the remote server.
Short Message Service (SMS)
Serial Over LAN (SOL)
Solution
1.Check if the LAN cable is connected to the right LAN port (usually LAN1 port) for server management. See page A‑1 for details.
2.Check if the remote server LAN port is working properly. If you have not previously installed the LAN controller driver, install the same using the system support CD.
3.Make sure that both LAN IPMI and
BMC firmware have been updated
(see section 2.3 for details), and the AC power cord has been unplugged for at least 5 seconds after the firmware updating.
4.Make sure that the IP address of both the remote and local/central servers are on the same subnet.
5.Try “ping <remote_server_ip>” in Windows command window or Linux/Unix terminal of local server (client), then type “arp
6.Reset BMC using “asmc2
Install SNMP service. See section 3.1.11 Viewing PET information for details.
1.Check if the USB cable is connected properly.
2.Check if your smart phone (such as ASUS P505) is working properly.
3.Install Microsoft® ActiveSync.
4.Set the phone number.
1.Check the BIOS remote console setting. See section 2.4 for details.
2.Check if the firmware baud rate is the same as the BIOS setting. See section 2.5.1 Configuring the LAN controller for details.
ASUS |