OPT1/2/3 Cable Overheat Protection [90]

Allows you to set the temperature over which the system automatically shuts down when any of the thermal sensor cables connected to the motherboard detects device overheat to protect the device from damage.

Configuration optitons: [Disabled] [50] [60] [70] [80] [90]

Fan Speed Monitor

Phoenix-AwardBIOS CMOS Setup Utility

Power

Fan Speed Monitor

 

Select Menu

CPU Fan Speed

4411

RPM

Item Specific Help

CHA_FAN1 Speed

0

RPM

 

CHA_FAN2 Speed

0

RPM

 

CHA_FAN3 Speed

0

RPM

 

OPT1 FAN Speed

0

RPM

 

OPT2 FAN Speed

0

RPM

 

OPT3 FAN Speed

0

RPM

 

PWR FAN Speed

0

RPM

 

 

 

 

 

CPU FAN, CHA _FAN1/2/3, OPT1/2/3 FAN, PWR FAN Speed

The onboard hardware monitor automatically detects and displays the CPU fan, chassis fan, optional fan, and power fan speed in rotations per minute (RPM). If any of the fans is not connected to the motherboard, the field shows 0. These items are not userconfigurable.

Fan Speed Control

Phoenix-AwardBIOS CMOS Setup Utility

Power

 

Fan Speed Control

 

Select Menu

CPU FAN Control

[Duty Cycle Mode]

 

Item Specific Help

CPU FAN Duty Cycle

[100%]

 

Select Fan Control

CHASSIS FAN Control

[Duty Cycle Mode]

 

 

mode.

CHASSIS FAN Duty Cycle

[100%]

 

 

 

x CHASSIS FAN Q-Fan Sense

CPU Temperature

 

 

OPT FAN1 Control

[Duty Cycle Mode]

 

 

OPT FAN1 Duty Cycle

[100%]

 

 

x OPT FAN1 Target Temperature

40ºC/104ºF

 

 

OPT FAN2 Control

[Duty Cycle Mode]

 

 

OPT FAN2 Duty Cycle

[100%]

 

 

x OPT FAN2 Target Temperature

40ºC/104ºF

 

 

OPT FAN3 Control

[Duty Cycle Mode]

 

 

OPT FAN3 Duty Cycle

[100%]

 

 

x OPT FAN3 Target Temperature

40ºC/104ºF

 

 

 

 

 

 

 

F1:Help

↑↓ : Select Item

-/+: Change Value

F5: Setup Defaults

ESC: Exit

→←: Select Menu

Enter: Select SubMenu

F10: Save and Exit

4-38

Chapter 4: BIOS setup