To create a RAID 1 set:
1.In the Main Menu, press <2> to enter the “Define LD” function.
2.Press <Enter>, and the following screen appears.
FastBuild (tm) Utility (c)
[ Define LD Menu ]
LD No | RAID Mode |
|
| Total Drv |
|
| |
|
|
|
|
|
| ||
LD 1 |
| RAID 1 | 2 |
|
| ||
Strip Block: |
| 64 KB | Fast Init: OFF |
| |||
Gigabyte Boundary: ON | Cache Mode: WriteThru | ||||||
|
|
|
| [ Define LD Menu ] |
|
| |
|
|
|
|
|
| ||
Channel:ID | Drive Model |
| Capacity (MB) |
| |||
Assignment |
|
|
|
|
|
|
|
1:Mas xxxxxxxxx | xxxxxx | Y | |||||
2:Mas xxxxxxxxx | xxxxxx | Y | |||||
3:Mas xxxxxxxxx | xxxxxx | N | |||||
4:Mas xxxxxxxxx | xxxxxx | N | |||||
|
|
|
|
|
|
| |
|
|
| [ Keys Available ] |
|
| ||
|
|
|
|
|
|
| |
[↑]Up [↓]Down | [ESC]Exit | [Space] Change Option |
3.Highlight the LD1 item and press <Space> to select RAID 1.
4.Move to the Assignment item by using the down arrow key and set Y to any two of the drives.
5.Press <Ctrl+Y> to save the setting. The utility prompts the following messages:
Press
key to ignore this option...
Press <Ctrl+Y> to erase MBR or press any key to continue.
Press
to use maxinum capacity...
Press <Ctrl+Y> to key in the desired capacity or press any key to continue.
6.The utility displays the following screen.
FastBuild (tm) Utility (c)
| LD No | RAID Mode |
| [ Define LD Menu ] |
| Status | |||
|
|
| |||||||
|
|
|
|
|
| ||||
|
| Total Drv | Capacity(MB) | ||||||
| LD 1 | RAID 1 | 2 | xxxxxx | Functional |
| |||
| LD 2 |
| |||||||
| LD 3 |
| |||||||
| LD 4 |
| |||||||
| LD 5 |
| |||||||
| LD 6 |
| |||||||
| LD 7 |
| |||||||
| LD 8 |
| |||||||
|
|
|
|
| [ Keys Available ] |
|
| ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| [↑]Up | [↓]Down |
|
| [ESC]Exit | [Enter] Select |
|
|
Chapter 5: Software support |