2.6Jumpers

1.Clear RTC RAM (CLRTC)

This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The RAM data in CMOS, that include system setup information such as system passwords, is powered by the onboard button cell battery.

To erase the RTC RAM:

1.Turn OFF the computer and unplug the power cord.

2.Remove the onboard battery.

3.Move the jumper from pins 1-2 (default) to pins 2-3. Keep the cap on pins 2-3 for about 5~10 seconds, then move the cap back to pins 1-2.

4.Replace the battery.

5.Plug the power cord and turn ON the computer.

6.Hold down the <Del> key during the boot process and enter BIOS setup to re-enter data.

P4P800 SE

CLRTC1

1

2

2

3

Normal

Clear CMOS

(Default)

 

 

P4P800 SE Clear RTC RAM

You do not need to clear the RTC when the system hangs due to overclocking. For system failure due to overclocking, use the C.P.R. (CPU Parameter Recall) feature. Shut down and reboot the system so BIOS can automatically reset parameter settings to default values.

2-20