5.2.5Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual drive. The

utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu.

The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the Check Consistency command:

1.From the Management Menu, select Check Consistency then press <Enter>.

LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011

BIOS Version A.11.02090932R

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC of VD(s)

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2.The screen displays the available RAID set(s) and prompts you to select the virtual drive to check. Press <Space> to select the virtual drive from the Virtual Drive sub-menu then press <F10>.

LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011

BIOS Version A.11.02090932R

 

 

 

 

 

 

 

 

 

Virtual Drive(s) Configured

 

 

Management Menu

LD

EasyRAID ConfSigurationze

-#StripesARRAY SELECTIONStripSzMENU

Status

Configure

0

1

148.580GB

2

64KB

ONLINE

Initialize

Objects

 

 

 

 

 

 

 

Rebuild

 

 

 

 

 

 

 

Check Consistency

 

 

 

 

 

 

 

Virtual Drives

Virtual Drive 0

Select VD

SPACE-(De)Select, F10-Initialize

ASUS P9D-I

5-27