CL1008 / CL1016 User Manual

F4: ADM

F4 is an administrator only function. It allows the administrator to configure and control the overall operation of the OSD. To change a setting, double click it; or use the up and down arrow keys to move the highlight bar to it then press [Enter].

After you select an item, a submenu with further choices appears. Double click an item, or move the highlight bar to it then press [Enter]. An icon appears before the selected item to indicate which one it is. . The settings are explained in the following table:

Setting

Function

 

 

SET USERNAME

This function is used to set usernames and passwords for the

AND

administrator and users:

PASSWORD

Š One administrator and four user passwords can be set.

 

 

Š After you select the administrator field or one of the user fields, a

 

screen that allows you to key in your username and password

 

appears. The username and password may be up to 15

 

characters long, and can consist of any combination of letters

 

and numbers (A–Z, 0–9).

 

Š For each individual, key in the username and password, then

 

press [Enter].

 

Š To modify or delete a previous username or password, use the

 

backspace key to erase individual letters or numbers.

 

 

SET LOGOUT

If there is no input from the console for the amount of time set with

TIMEOUT

this function, the operator is automatically logged out. A login is

 

necessary before the console can be used again.

 

This enables other operators to gain access to the computers when

 

the original operator is no longer accessing them, but has forgotten

 

to log out. To set the timeout value, key in a number from 1–180

 

minutes, then press [Enter]. If the number is 0 [zero], this function

 

is disabled. Default is 0 (disabled).

 

 

 

(Continues on next page.)

28