4. OSD Operation

 

 

 

 

 

 

 

 

Setting

Function

 

 

SET ACCESSIBLE

This function allows Administrators and Users to select which

PORTS

Ports can be accessed from a particular Console. Move the

 

highlight bar to the target computer, then press [Enter] or the

 

[Spacebar] to toggle access On and Off. If access is On, a

 

plus mark ( + ) appears to indicate so. If access is Off, the

 

area is blank. Make your choice, then press [Esc] to confirm.

 

 

SET MULTIUSER

This function determines whether or not the same ID can be

MODE

used to log into the CS428 from different Consoles at the

 

same time.

 

1. If Disabled, the same ID cannot be used; if Enabled (the

 

default), the same ID can be used to log in from more than

 

one Console.

 

2. If Enabled, the F4, F6, and F7 settings set for any one

 

Console, will be the same for all other Consoles that log in

 

with the same ID.

 

3. Changes made to the F4, F6, and F7 settings by any

 

logged in Console will automatically affect all Consoles

 

with the same ID.

 

 

SET ACCESS

This function is used to set the timeout value to control the

TIMEOUT

release of access rights to a computer. If the original Console

 

doesn't access the computer before the timeout value is

 

reached, the computer becomes available to the other

 

Consoles. To set the timeout value, key in a number from 2 -

 

255 seconds, then press [Enter] (if the number is 0 [zero],

 

this function is disabled. Default is 010 (ten) seconds.

 

 

CLEAR THE NAME

This function is used to undo all Administrator changes and

LIST

return the setup to the original factory default settings.

 

Note: While this function is in progress, make sure that no

 

other operations are performed on any of the other Consoles.

 

 

RESTORE DEFAULT

This function is used to undo all Administrator changes and

VALUES

return the setup to the original factory default settings - except

 

for the Names that were assigned to Ports, which are saved.

 

 

RELEASE ALL

Releases all Ports that have been set to Private Mode (see

PRIVATE

PRIVATE MODE, page 23), so that they become accessible

 

to all Consoles.

 

 

SET LOGOUT

If a Console that has accessed a computer isn't used for the

TIMEOUT

amount of time set with this function, the Operator is

 

automatically logged out. A login is necessary before the

 

Console can be used again. This enables the other Consoles

 

to gain access to the computers when the original Console is

 

no longer accessing them, but the Operator has forgotten to

 

relinquish access. To set the timeout value, key in a number

 

from 1 - 255 minutes, then press [Enter] If the number is 0

 

[zero], this function is disabled. Default is 5 (five) minutes.

21