4. OSD Operation

(Continued from previous page.)

Setting

Function

 

 

SCAN DURATION

Determines how long the display dwells on each port when it

 

cycles through the selected ports in Quick View Scan Mode.

 

Key in a value from 1 - 255 seconds, then press [Enter].

 

Default is 3 seconds.

 

 

PRIVATE MODE

The [Enter] key is a toggle that Enables/Disables Private

 

Mode for the currently selected port. When Private Mode is

 

Enabled, none of the other Consoles cannot access the port,

 

and their monitors show a blank screen when they come to it.

 

If another console tries to access the port, the message:

 

Private Mode: Console x (where x represents the number of

 

the console that has set private mode for the port), displays

 

on its screen.

 

When you have finished making your selections, press [Esc]

 

to return to the OSD Main Menu.

 

 

RESTORE DEFAULT

This function is used to undo all User changes and return the

VALUES

setup to the original factory default settings - except for the

 

Names that were assigned to Ports, which are retained.

 

 

MOUSE BUTTON

This function allows you to set the mouse for right or left

SETUP

handed operation. Use [Enter] to toggle between the two.

 

 

SET PASSWORD

This function is for Users to set their passwords:

 

1. When you access this function, if you already have a

 

password you must enter it in order to continue.

 

2. A screen appears that allows you to key in your new

 

password. The password may be up to 8 characters long,

 

and can consist of any combination of letters and numbers

 

(A - Z, 0 - 9).

 

3. To modify or delete a previous password, use

 

[Backspace] to delete the characters.

 

4. Key in the password, then press [Enter]. You are asked to

 

key the password in again, in order to confirm that it is

 

correct. Key in the new password again, then press

 

[Enter].

 

If the two entries match, the new password is accepted. If

 

the entries do not match, you must start again from the

 

beginning.

 

 

23