CS82U / CS84U User Manual

Auto Scanning

The CS82U / CS84U’s Auto Scan feature automatically cycles the KVM focus through the computer ports at regular intervals. This allows you to monitor the computer activity without having to take the trouble of switching from port to port manually. See the table below for details.

Hotkey

 

Action

 

 

[Scroll Lock] [Scroll

Invokes Auto Scan. The KVM focus cycles from port to port

Lock] [A] [Enter]

at 5 second intervals. Five second intervals is the Default

 

setting.

 

 

[Scroll Lock] [Scroll

The KVM focus cycles from port to port at n second intervals.

Lock] [A] [Enter] [n]

Replace the n with a number between 1 and 4 when entering

 

 

this hotkey combination to set the number of seconds that

 

the CS82U / CS84U should dwell on a port before moving on

 

to the next, as follows:

 

1

= 3 seconds

 

2

= 5 seconds (default)

 

3

= 10 seconds

 

4

= 20 seconds

 

 

 

Note: 1. While Auto Scan Mode is in effect, ordinary keyboard and mouse functions are suspended – only Auto Scan Mode compliant keystrokes and mouse clicks can be input. You must exit Auto Scan Mode in order to regain normal control of the console.

2.Although the video focus switches from port to port, the keyboard and mouse do not switch. They stay at the port they were on when Auto Scanning started.

3.To exit Auto Scan Mode, press the Esc key or the Spacebar.

16