Chapter 4. Administration
(Continued from previous page.)
Property Settings
To set up the serial communications parameters for a port, select it, then click the Property Settings button at the bottom of the page:
The meanings of the settings are given in the following table:
Setting | Meaning |
|
|
Port ID | Each port on the SN0108 / SN0116 has a port ID number (COM1 - |
| COM8 for the SN0108, or COM1 - COM16 for the SN0116). The Port |
| ID field displays the number of the port that is being configured. |
|
|
Port Name | You can give a port an appropriate name by editing the Port Name |
| field. |
|
|
Baud Rate | This sets the port’s data transfer speed. Choices are from 300 – |
| 115200 (drop down the list to see them all). Set this to match the |
| baud rate setting of the connected device. Default is 9600 (which is a |
| basic setting for many serial devices). |
|
|
Data Bits | This sets the number of bits used to transmit one character of data. |
| Choices are: 5, 6, 7 and 8. Set this to match the data bit setting of the |
| connected device. Default is 8 (which is the default for the majority of |
| serial devices). |
|
|
| (Continues on next page.) |
33