EDID Mode Selection Commands

Extended Display Identification Data (EDID) is a data format that contains a display's basic information and is used to communicate with the video source/system. You can set which EDID mode the VM0404H uses with the following command:

EDID Command + Control + [Enter]

For example, to pass the EDID from Port 1 to all sources, type the following:

edid port1 [Enter]

The following tables show the possible values for commands:

Command

Control

Description

 

 

 

edid

port1

The EDID from Port 1 will be passed to all video

 

 

sources

 

 

 

edid

remix

Implement the EDID of all connected displays. The

 

 

VM0404H uses the best common resolution

 

 

applicable for all displays

 

 

 

edid

default

Implement default EDID for all (default)

 

 

 

Reset Commands

The formula for Reset commands is as follows:

Reset Command + [Enter]

For example, to reset the device back to the default factory settings, type the following:

reset [Enter]

The following table shows the possible values for commands:

Command

Description

 

 

reset

Reset device back to factory default settings

 

 

Verification

After entering a command, a verification message appears at the end of the command line as follows:

ŠCommand OK - indicates that the command is correct and successfully performed by the switch

ŠCommand incorrect - indicates that the command has the wrong format and/or values

- 19 -