OnePower Line Interactive UPS (EN)

5.When UPS is operating, press POWER button and hold 3 seconds until switch off (Switch off UPS, must turn off the equipment which connect to UPS, Then press POWER button).

IMPORTANT NOTICE: Plug the UPS into the wall outlet to charge the UPS for over 10 hours before using the UPS.

IMPORTANT NOTICE: Before

connect

with equipment

power supply line,

please

count the

total

equipment watt. The number must lower than UPS

output

watt. If

it

higher

than

UPS

output watt, please reduce some

equipment, or

UPS will

lock

under

backup power

condition (No output

of UPS, display OVERLOAD or FAULT).

1.8 Front Panel Explanations

On the front panel You can found 3 LED for an easy diagnostic.

LEDInformation

Main Switch(4) To Control on/off the UPS when Utility is normal.

To enable “DC-Start” Function when Utility fails. (To enable DC Start properly, you are recommended to connect <80% output load with the UPS only). P.S. Make sure the computer connected to the UPS is switched on before enable the "DC-Start" function. You are not recommended to add some other computer or peripherals after DC-Start function is activated.

NORMAL(1) Green LED remains standstill when Utility is normal.

A03-PS651

Pag. 21