Table 1

Panel Inches

Resolution

Pixel Number

15”

1027 x 768

786,432

17”

1280 x 1024

1,310,720

 

 

 

19”

1600 x 1200

1,920,000

 

 

 

This Norm identifies five different kind of damage (Table 2). For every one of them it indicates the maximum acceptable defectiveness, divided in quality class. It is indicated in: number of damages for every million of pixels (Table 3).

Table 2

TYPE 1

TYPE 2

TYPE 3

CLUSTER 1

CLUSTER 2

Table 3

Full Pixel continuously turned on (white point)

Full Pixel continuously turned off (black point)

1 or 2 subpixels continuously turned on or off, or Intermittent Spot.

More than a Type 1 or 2 damage in a 5 pixel x 5 pixel area

More than a Type 3 damage in a 5 pixel x 5 pixel area

Panel Class

Type 1

Type 2

Type 3

Cluster 1

Cluster 2

I

0

0

0

0

0

II

2

2

5

0

2

III

5

15

50

0

5

IV

50

150

500

5

50

3.3 Atlantis Land Warranty term Conditions

Atlantis Land S.p.A. gives you better Substitution Conditions than Class 2 (Class 1 panels are used for Medical and military machines only). Table 4 indicates maximum defectiveness limits in Subpixels (1 Pixel = 3 Subpixels) and are different for every kind of panel.

 

Table 4

 

 

 

Panel Inches

 

 

 

 

 

 

 

 

 

15”

 

 

17”

 

 

Subpixel always

 

3

 

4

 

 

Turned On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subpixel always

 

3

 

4

 

 

turned Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subpixel turned on

 

4

 

5

 

 

or off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19”

4

8