Atlas MLGS180W, MLGS180B Installation, Wire The Light Control, Red Sensor Wire to, White to White

Models: MLGS180W MLGS180B

1 4
Download 4 pages 26.77 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp

screw.Controls Clamp Screw WIRE THE LIGHT CONTROL.

Rotate the sensor head clockwise 180° so the controls face down.

Controls

❒Turn power off at the fuse or circuit breaker. Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

These instructions show the sensor wired to flood- lamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (Up to 500 Watts, 4.2A Maximum) is placed across the white and red wires.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture, if present.

After screwing the sensor into the wall plate, connect the junction box wires to the Light Control wires by twisting together and securing with wire connectors.

 

 

Red Sensor Wire to

White to White

 

Black Lamp Wire

 

 

 

Junction

Box

Lamp Holders

Black to Black

Optional:Connectadditionalloadacross the white and red wires. Total lighting loadincludinglampheadsonfixturemust not exceed 500 Watts (4.2A).

MOUNT THE LIGHT.

Follow the instructions that came with your light fixture for mounting and adjusting the light fixture.

Keep regular PAR-38 lamps at least 1" (25 mm) from the sensor. Halogen lamps should be kept at least 2" (51 mm) from the sensor.