Atlas MLGS180B Test And Adjustment, Specifications, On-Timerange, Bottom of Sensor, Maximum Range

Models: MLGS180W MLGS180B

1 4
Download 4 pages 26.77 Kb
Page 3
Image 3
TEST AND ADJUSTMENT
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIMERANGE

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

180°

(2.4m)

 

70 ft.

 

(21m)

 

Maximum Range
Maximum

 

Coverage Angle

The sensor is less sensitive to motion directly towards it, most sensitive to motion across its field of view.

MotionMotion

 

 

 

 

 

 

 

 

 

Sensor

Least Sensitive
Most Sensitive

Loosen the clamp screw in

Clamp

the sensor ball joint and

Screw

gently rotate the sensor.

 

Walk through the cover-

Ball

age area noting where you

Joint

are when the lights turn on

 

(also, the LED will flash

 

several times when motion

 

is detected). Move the sen-

 

sor head up, down, or side-

Aim Sensor

ways to change the cover-

Down for Short

age area. Keep the sen-

Coverage

sor at least 1" (2.5 cm)

 

away from the lamps.

 

Adjust the RANGE as

needed. RANGE set too high may increase false triggering.

Secure the sensor head

by tightening the clamp screw. Do not over- tighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . . . Up to 180°

Electrical Load . . . . . . . . Up to 500 Watt (4.2A) Maxi- mum Incandescent [Up to 250 Watt maximum each lamp holder.]

Power Requirements . . . 120 VAC, 60 Hz

Operating Modes . . . . . . TEST, AUTO and MANUAL MODE

Time Delay . . . . . . . . . . 1 , 5, 10 minutes Range . . . . . . . . . . . . . . Adjustable

Atlas Lighting Products, Inc. reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.