8.EPD “Emergency Power Down” Port - When an urgent system shut down is required, short the two pins together and the sequence portion will be bypassed and turn Off all outputs at the same time. This EPD feature is commonly used with fire control systems.

9.Delay Pot for Sequence 1 Output - The time between Sequence 1 Output and Sequence 2 Output can be set by rotating the pot following the indicators on the panel. In X1 mode the delay time adjustment is from 1 second to 60 seconds. In X10 mode the delay time adjustment is from

10 seconds to 600 seconds, or 10 minutes. See the Function Settings below for Sequence 1 Output

X1 or X10 configuration.

10.Delay Pot for Sequences 2-6- The time between Sequence 2 Output and Sequence 6 Output can be set by rotating the pot following the indicators on the panel. Whatever the time is set to will be the time between Sequenced outputs.

11.Cable Management Retainer Points - Use the rear panel screws for connecting the included cable retainers. Each TSD comes with two cable retainers for simplified cable management.

Dip Switch Function Identification

SWITCH FUNCTIONS

Switch Position

DIP SW # 1-6 - Channel Output Assignment - Each output can be assigned to deliver a Hard

Switch Contact Closure (CC) or +24VDC output when activated by the Sequence for Output Channels 1-6.

DIP SW # 7 - Link Assignment Configuration - This switch determines if the unit is to be a

Master or a Slave unit. The Master unit is always the first in line of the sequence.

DIP SW # 8 - Sequence Output 1 Time Delay - In the X1 setting the adjustable time delay setting is from 1s to 60s and in the X10 position the time delay setting is from 10s to 600s, or 10 minutes.

Mounting

There are three ways to securely mount this TSD:

1.Velcro™ - Each unit includes industrial-grade Velcro™ with adhesive backing to adhere to any flat surface.

2.Brackets - Each unit includes two mounting brackets to secure to a cabinet or wall.

3.Rack Mount Panel - The optional TSD-RMK rack mount panel supports up to four TSDs in a

1RU space.

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

– 5 –

AtlasSound.com

Specifications are subject to change without notice.

Page 5
Image 5
Atlas Sound TSD-SEQ6 owner manual Dip Switch Function Identification, Switch Position, Mounting