RS-232

Connection

RS-232 is connected through a 9-pin female D connector. The pins will have functions

associated with them, some will be unassigned.

No. Pin Function
1 ---- Not used
2 Tx Transmit
3 Rx Receive
4 ---- Not used
5Gnd Ground
6 ---- Not used
7 ---- Not used
8 ---- Not used
9 ---- Not used
1
2
3
4
5
9 8 7 6

Command

The command codes are very sensitive, do not change capitalization, spacing, or lettering.

Command Feedback Description
PWON PWON Power on
PWOFF PWOFF Power off
All# x1AVx1, x2AVx2, ... Resets all inputs to corresponding outputs (in3 to out3)
x1$ x1$ Turns off output channel (to turn off output 3 = x3$)
x1AVx2 x1AVx2 Switch input to output (input 3 to output 5 = x3AVx5)
x1AVx2,x3,x4 x1AVx2,x3,x4 Switch input to multiple outputs (input 3 = x3AVx1,x2)
RS232zoneX[command]
ex: RS232zone1[PWON]
RS232zoneX[command]
ex: RS232zone1[PWON]
Send commands to devices connected to the receiver RS-232 ports.
Commands are the same as the ones stated in this table.
X = zone number
example: Turning the power on for the device connected in zone 1
Statusx1 x7AVx1 Shows what input is connected to selected output
Status x1AVx1, x2AVx2,
x3AVx4, ....
Displays which inputs are currently connected to which outputs
SaveY (ex. Save2) SaveY (ex. Save2) Saves settings for future use, preset options 0 to 9
RecallY (ex. Recall2) RecallY (ex. Recall2) Recalls saved settings for the number you selected
ClearY (ex. Clear2) ClearY (ex. Clear2) Erases the save for the number you selected
Mreset Mreset Sets matrix back to the default settings

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”