RS-232 Set Up

To set up the RS-232 hyperterminal (if not using 3rd party software) the first thing needed is to find the RS-232 communications port under the computer’s device manager. Once there right click the port and select properties. Under the properties menu select the port settings tab and update the menu to the matrix default: Bits Per Second: 115200, Data Bits: 8, Parity: None, Stop Bits: 1 and Flow Control: None.

Baud Rate

To change the baud rate of the matrix or the receivers (i.e. AT-PRO2HDREC or AT-PRO21616M-RX) an RS-232 hyperterminal will be needed. Once the RS-232 hyperterminal is set up changing the baud rate will be done with a command line. The baud rate for the matrix is for matrix control and the output baud rate is for control of the RS-232 device in the zone being altered.

Note: Baud Rate must be only 2400, 4800, 9600, 19200, 38400, 57600, or 115200

To view the current baud rate of the Matrix: select function, press 8, and then press 4.

home screen

AT-PRO2HD88M

Select Input Number

----->Select function option

----->

AT-PRO2HD88M

FW Ver: 1.0.X

----->

AT-PRO2HD88M

Console: 115200 8 None 1

To view the current baud rate of the Outputs: select function, press 8, and then press 5 (press 5 repeatedly to cycle through each output).

home screen

AT-PRO2HD88M

Select Input Number

----->Select function option

----->

AT-PRO2HD88M

FW Ver: 1.0.X

----->

AT-PRO2HD88M

Port x: 9600 8 None 1

 

 