RS-232 Command for the Output baud rate status

RS-232 Command for the Output baud rate status

RS232para

The RS-232 status command will provide feedback for the current parameters for each output. Example: (See example of feedback below)

RS232para

Current RS232 parameter:

-Port 1 :BaudRate 2400bps, DataBits 0, Parity None, StopBits 1.

-Port 2 :BaudRate 9600bps, DataBits 0, Parity ODD, StopBits 1.

-Port 3 :BaudRate 9600bps, DataBits 0, Parity None, StopBits 1.

-Port 4 :BaudRate 9600bps, DataBits 0, Parity None, StopBits 1.

Note: Default for the outputs is: Baud-9600bps, Data length-8bit, Parity-None, Stop Bit-1

The ability to check baud rate status on the outputs will help to identify control compatibility for in zone RS-232 devices.

Command for Output (receiver) baud rate

RS232paraX[baudrate,data-length,parity,stop-bit]

X represents the zone# (output#), the data length must be 7 or 8, partity bit will be 0 for none, 1 for odd, 2 for even, and the stop-bit must be 1 or 2.

For example if you wish to change the baud rate to 19200, data length 8, ODD parity, and 1 stop-bit on the receiver in zone 3 to 19200 the command would look like this:

RS232para3[19200,8,1,1]