Table 6.2 Operator Troubleshooting for ATN NVM-14

Malfunction

Test or inspection

Corrective Action

 

 

 

1. Monocular fails to

Visual.

Turn switch to OFF position and then

activate.

 

ON.

 

Check for defective, missing or improp-

Replace batteries or install correctly.

 

erly installed batteries.

 

 

 

 

2. IR illuminator fails

In a dark location with system turned on,

If IR illuminator fails to activate, refer to

to activate.

activate IR. Visually check IR illuminator

higher level of maintenance.

 

operation; scene should brighten.

 

 

 

 

3. IR indicator fails

Visual.

Refer to higher level of maintenance.

to activate.

 

 

 

 

 

4. Poor image

• Check objective lens or ey piece focus.

•Refocus.

quality

• Check for fogging or dirt on lens.

•Clean lens surface.

 

 

 

• If image quality is still poor, refer to

 

 

higher level of maintenance.

 

 

 

5. Light visible

• Check eye-relief distance.

• Readjust for proper eye-relief distance.

around eyecup

• Check eyecup for resiliency.

• If eyecup is defective, refer to higher

 

 

 

level of maintenance.

 

 

 