ATTO Technology FC-84EN, FC-81EN operation manual Celerity FC-82EN Adapter

Models: FC-81EN FC-82EN FC-84EN

1 42
Download 42 pages 54.92 Kb
Page 7
Image 7

Celerity FC-82EN Adapter

The ATTO Celerity FC-82EN leverages two next- generation storage technologies: PCIe 2.0 interconnect and 8-Gigabit Fibre Channel.

With 8-Gb FC speeds of up to 1600 MB/sec. per channel, the Celerity FC-82EN supports the most demanding application requirements, including high- definition video, rich content databases and other high-bandwidth environments.

ATTO Celerity host adapters are an integrated family of advanced storage connectivity solutions that are designed to provide reliable connectivity, intelligence and scalability.

Technical specifications

Two independent Fibre Channel ports

1600 MB/sec. maximum throughput per channel in full-duplex mode

8-Gigabit data transfer rates

Conforms to PCI Express Low Profile form- factor specifications

Supports all FC topologies: fabric, arbitrated loop and point-to-point

ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC- AL2, FC-PLDA, FC-FLA

Flash ROM for easy field upgrades

FC Class 3 support

Local management and diagnostics

Buffer credits: 41

ATTO Advanced Data Streaming (ADS™) Technology

Advanced FC capabilities

Supports SNIA HBA API

Backward compatible with 4-Gb and 2-Gb Fibre Channel

Supports target and initiator modes

Supports Windows® FDMI and WMI

Host bus specifications

x8 mechanical and x8 electrical PCI Express interconnect

Conforms to PCI Express Base Spec 2.0 Conforms to PCI Express CEM Spec 2.0

PCI Hot Plug spec 1.0

Environmental & physical specifications

Length: 6.6 inches

Height: 2.731 inches

Operating temperature: 0-40 ºC (32-113 ºF)

Storage temperature: -40 to 70 ºC (-40 to 158 ºF)

Relative humidity: 10 to 90% non-condensing

5.9W (typical)

100 lf/m (minimum) airflow recommended

RoHS compliant

External connectivity

Easy to install full height connection bracket; low-profile bracket included in finished goods packaging

External LEDs for on-line and speed status for each channel

Two pluggable 8-Gb optical LC SFP+ modules included

Software specifications

Windows 7®, XP®, Vista®

Windows Server® 2003, 2008

Mac® OS X 10.4.x and up

RedHat Enterprise Linux® 4.x (2.6.x kernels)

RedHat Enterprise Linux® 5.x (2.6.x kernels)

RedHat Enterprise Linux® 6.x (2.6.x kernels)

SUSE Linux Enterprise® 9.x (2.6.x kernels)

SUSE Linux Enterprise® 10.x (2.6.x kernels)

Fedora Core Linux® 7.x (2.6.x kernels)

Fedora Core Linux® 8.x (2.6.x kernels)

VMware ESX Server® 3.5 - 4.1

3