**POTTED CHANNEL CIRCUIT BOARDS Atwood **potted circuit boards can be tested using a multi-meter. This test must be performed with the circuit board removed, and the meter set to the ohms scale. This will check the continuity of all tracks on the harness connection of the board.

The following steps should be used to test each track.

A. Cross leads of meter to ensure it is registering continuity.

B.TO TEST POWER TRACK:

Place negative lead of the multi-meter to ground (green wire) track of edge connection and positive lead of the multi-meter to top power (brown wire) track of edge connection. If no continuity, board is defective. *Atwood does not warranty this installation related failure.

C.TO TEST LAMP TRACK:

Place negative lead of the multi-meter to ground (green wire) track of edge connection and positive lead of the multi-meter to lamp (blue wire) track of edge connection. If no continuity, this indicates blown lamp track. Circuit board will still fire unit but lamp light will not come on. This is caused by a short in the blue wire between the unit and the switch. Wiring must be corrected before the board is replaced. *Atwood does not warranty this installation related failure.

D.TO TEST VALVE TRACK:

Place negative lead of the multi-meter to ground (green wire) track of edge connection and positive lead of the multi-meter to valve (red wire) track of edge connection. If no continuity, this indicates a blown valve track.

If the valve wire is shorting under the flue box – Atwood will warranty the board.

If the E.C.O. terminals are contacting the drawn pan

– Atwood will warranty the board only if the inner tank of the water heater was installed flush on the floor of the coach.

If the inner tank of the water heater does not rest flush against the floor of the coach –*Atwood does not warranty this installation related failure.

*Installation related failures on circuit boards are the responsibility of the coach manufacturer.

**Non potted circuit boards can be checked by turning the board over and visually inspecting each track for a burn mark or break in the track itself. A burn mark or broken track indicates the board is blown. Depending on which track is blown determines whether it is covered under Atwood’s warranty as stated in section B, C and D.

THERMAL CUT-OFF DEVICE

Current Atwood direct ignition water heaters are equipped with a thermal cut-off device. This device is located on the incoming power wire and is connected to the thermostat. The thermal cut-off is designed to permanently break circuit and shut down the water heater before excessive heat can cause damage due to obstructions in the main burner tube or flue tube caused by spiders or mud wasps. These obstructions can cause the main burner flame to burn outside the main burner tube. When the flame or the heat from the flame contacts the thermal cut-off, the circuit will open.

If there is no heat damage to the thermal cut-off, and if it is determined defective, Atwood will cover the replacement of this device under warranty. We will allow .25 hour at your Atwood approved warranty rate. If there is heat damage the device performed its safety feature and no warranty labor will be allowed. Any obstructions should be removed, alignment checked and gas pressure taken before a new thermal cut-off is installed.

Note: When replacing a thermal cut-off, also examine the grill in the access door while the door is in the closed position. The wide aluminum band of the grill should be at the bottom. If it is at the top, this condition may trap exhaust heat and possibly also cause thermal cut- off to trip. To correct, remove the grill from the door and snap back in place with the wide aluminum band at the bottom.

THERMOSTAT

The thermostat on this water heater is pre-set at 140° F. The water heater will cycle off when the water temperature reaches 140° F. and will generally take 20-25 minutes to reach this temperature. It will cycle back on when the water temperature cools down to approximately 115° F. In the latter part of the heating cycle though, it is very common for the pressure-temperature relief valve to weep. Refer to the page covering weeping relief valves to remedy this situation.

If a customer is dissatisfied with the temperature of the water, first check the water temperature with a cooking thermometer and verifying that the initial cycle is within the time noted above. If not, an adjustable thermostat may be purchased allowing the water temperatures to be adjusted from 110 - 150° F. It fits in place of the original thermostat.

23

Page 23
Image 23
Atwood Mobile Products 94605 To Test Power Track, To Test Lamp Track, To Test Valve Track, Thermal CUT-OFF Device

94605 specifications

Atwood Mobile Products 94605 is a robust and reliable solution designed to cater to the needs of RV and trailer enthusiasts. This product has gained considerable attention in the market due to its exceptional build quality, innovative features, and user-friendly design.

One of the standout characteristics of the Atwood 94605 is its high efficiency. Designed specifically for recreational vehicles, this product ensures optimal performance, reducing energy consumption while maximizing output. The incorporation of advanced heating technologies allows for quicker heating times and consistent temperature regulation, making it ideal for both short trips and extended outdoor adventures.

The Atwood 94605 is equipped with a lightweight and compact design, allowing for easy installation and integration into various RV models. Its low-profile construction not only minimizes the space it occupies but also enhances its compatibility with numerous vehicle layouts. This careful consideration of design ensures that users can enjoy the benefits of this product without sacrificing space or aesthetic appeal.

Durability is another key feature of the Atwood 94605. Constructed from high-quality materials, this product is built to withstand the rigors of travel and changing weather conditions. This resilience means that users can depend on the Atwood 94605 for years to come, ensuring peace of mind during their adventures.

The ease of use is also a significant aspect of the Atwood 94605. The product boasts straightforward controls that make it accessible for all users, whether they are seasoned RVers or newcomers to the camping experience. The user-friendly interface simplifies the heating process, allowing users to focus on enjoying their trips rather than fussing over complicated systems.

Safety features are paramount in the design of the Atwood 94605. It includes multiple safety mechanisms to prevent overheating and provides users with an added layer of security while in operation. These built-in protections contribute to the overall reliability and trustworthiness of the product.

In conclusion, Atwood Mobile Products 94605 offers an impressive combination of efficiency, durability, and user-friendly operation. With its high-quality construction and advanced heating technology, this product is designed to enhance the RV experience, making it a valuable addition to any outdoor enthusiast's toolkit. Whether embarking on a weekend getaway or a cross-country adventure, the Atwood 94605 is engineered to deliver performance and reliability.