3.3 Master Thermostat - Installation and Wiring

3.3 Master Thermostat - Installation and Wiring

WARNING: Make sure all slave units are in STANDBY mode.

Required parts: TH113-A/F/AF (12VDC), TH114-A/F/AF (12VDC), TH115-A/F/AF (12VDC) or TH116-A/F/AF (12VDC)

Location: anywhere easily accessible to users.

Temperature control: AF (ambient with floor limit) / A (ambient)

Install the master thermostat in the controlled area.

Choose a location about 5 ft. above the floor in an area where the tempera- ture is stable.

Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.

Temperature control: F (floor)

Can be installed anywhere.

sWire the 12 VDC base to the nearest slave unit.

The floor sensor must be installed in an area where average temperature can be read. The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire.

For maximum performance, the sensor probe should be centered between the wires in the mat (max. 80°C).

tPush the excess wire into the wall, secure the base using the provided screws and wall anchors, and install the TH11x thermostat onto the base.

uOnce the thermostat is installed, return power to heating system and switch all slave units and the master thermostat to ON.

3.4 Slave Units - GFCI Test

We recommend you test the GFCI immediately after installing the thermostat, and once a month thereafter to ensure it is operating properly.

If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and verify the installation.

nSlide the protective door upwards and make sure the switch is ON. o Press TEST.

The test is successful if the TEST warning light is ON and power is cut off.

If the test fails (first installation test):

a.Verify installation

b.Check the load wires

c.Once you've identified the problem, run the GFCI test again

If the test fails (monthly maintenance):

a.Cut power to heating system from the main power panel and call customer service

pWhen the test is successful, reset the slave unit by switching from ON to STANDBY then back to ON.

qRepeat steps 1 to 3 for all slave units.

Technical Specifications

Temperature:

-Operation: 32°F to 122°F (0°C to 50°C)

-Storage: -4°F to 122°F (-20°C to 50°C)

TH113/TH114/TH115/TH116 (A/F/AF-12VDC)

Power supply

12 V from remote unit

Maximum

up to 10 slave units per

slave units

master thermostat

Wire gauge

20 AWG

 

 

Size (H • W • D)

4.63 x 2.7 x 0.61 in.

BASE

(117.5 x 68.3 x 15 mm)

NOTE: Refer to the TH11x user guide for technical specifications.

CT230-120GA/120GB/240GA/240GB

Supply

 

- PB112-120

1800 W @ 120 VAC

 

60 Hz, 15 A resistive

- PB112-240

3600 W @ 240 VAC

 

60 Hz, 15 A resistive

 

 

GFCI

GA=5 mA / GB=30 mA

 

 

Certification

c CSA us

 

 

Size (H • W • D)

4.63 x 2.7 x 1.45 in.

BASE

(117.5 x 68.3 x 37 mm)

Size (H • W • D)

4.67 x 2.74 x 0.67 in.

INTERFACE

(118.6 x 69.6 x 17 mm)

Warranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under nor- mal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).

If the product is defective,

(i)return it, with a bill of sale or other dated proof of pur- chase, to the place from which you purchased it, or

(ii)contact Aube. Aube will make the determination whether the product should be returned, or whether

a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.

Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD- UCT. Some provinces, states or regions do not allow the exclusion or limitation of incidental or consequential dam- ages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR- RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or regions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from province, state or region to another.

Service

For any questions regarding the product installation or operation, contact us at:

705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8

Canada

Tel.: (450) 358-4600

Toll-free: 1-800-831-AUBE

Fax: (450) 358-4650

E-mail: aube.service@honeywell.com

For more information on our products, visit us at:

www.aubetech.com

400-230-000-D 2/7/07 2/2