Specifications
| SUDP4000I | SUDP6000I |
| SUDP8000I |
| SUDP10000I | |
Acceptable input voltage |
|
|
| 220/230/240V |
|
| |
|
|
| |||||
|
| ±10% bypass operation |
| ||||
Input voltage |
| 220/230/240 | VAC |
| |||
230 volt output range |
| 220/230/240 VAC |
| ||||
Nominal input frequency |
|
| 50 or 60 Hz |
| |||
Input protection |
| Resettable circuit breaker |
| ||||
Frequency limits |
| 50 or 60 Hz, | 8% |
|
| ||
Bypass Transfer time |
| 2 ms typical, 5 ms maximum |
| ||||
Maximum load, Total | 4000 VA | 6000 VA |
| 8000 VA |
| 10000 VA | |
|
|
| 230 VAC |
| |||
| 50 or 60 Hz, | 0.1 Hz; |
| ||||
|
| unless synchronized to utility during brownout. |
| ||||
|
| ||||||
Overload protection | Overcurrent and | ||||||
Overload protection | 25A | 40A |
|
| 50A |
| 63A |
Noise filter |
| Normal and common | mode EMI/RFI suppression, | ||||
|
| 100 kHz to 10 MHz |
| ||||
Battery type |
| Spill proof, maintenance free, sealed |
| ||||
Typical battery life |
| 5 years, depending on number of discharge cycles | |||||
|
| and ambient temperature |
| ||||
Typical recharge time |
| 24 hours from total discharge |
| ||||
Operating temperature |
| 0 to 40C (+32 to +104F) |
| ||||
Storage temperature |
|
| |||||
Operating and storage relative humidity |
| 30% to 95%, not condensing |
| ||||
Operating elevation |
| 0 to +3,000 m (0 to +10,000 ft.) |
| ||||
Storage elevation |
| 0 to +15,000 m (0 to +50,000 ft.) |
| ||||
Electromagnetic Compatibility (EMC) |
|
|
| ||||
Electromagnetic Interference (EMI) |
| EN55022 Class A |
| ||||
Electromagnetic Immunity |
| IEC |
| ||||
|
| ||||||
Audible noise in dBA at 1 m (3 ft.) |
|
| 45 dBA |
|
|
| |
Safety approvals |
| GS licensed by VDE to | |||||
Size (W x H x D) |
| 315 x 650 x 610 mm |
| ||||
Weight | 128 kg |
|
|
| 138 kg |
|
Limited Warranty
American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support (see the Service section of the User’s Manual). Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.