Configuration Menu

Item

Parameters

Display

Options

Default

Description

 

 

 

 

 

 

1

Time format

 

12 Hr / 24 Hr

24 Hr

Select the time display format.

 

 

 

 

 

 

 

 

 

 

 

On: Heating or cooling starts in advance (as determined by the

 

 

 

 

 

controller) so that the desired temperature is attained at the set

 

 

 

 

 

times.

2

Early Start

 

On / OF

OF

OF (Off): Heating or cooling starts at the set times.

 

NOTE: Early Start applies for periods 1 and 3 (P1 and P3) only.

 

 

 

 

 

 

 

 

 

 

When this feature is enabled, heating or cooling will start in

 

 

 

 

 

advance of the set time for P1 and P3 but will start at the set

 

 

 

 

 

time (not earlier) for P2 and P4.

 

 

 

 

 

 

 

 

 

 

 

OF (Off): The normal time is used all year long.

 

 

 

 

 

1 : The controller switches to daylight savings time on the first

 

Automatic daylight

 

 

 

Sunday of April and to normal time on the last Sunday of Octo-

3

 

OF / 1 / 2

OF

ber.

savings adjustment

 

 

 

 

 

2 : The controller switches to daylight savings time on the second

 

 

 

 

 

 

 

 

 

 

Sunday of March and to normal time on the first Sunday of

 

 

 

 

 

November.

 

 

 

 

 

 

4

Temperature scale

 

°C / °F

°C

Select the temperature display format.

 

 

 

 

 

 

5

Balance point low

 

-30°C to 10°C

-10°C

Set the bP L value (see section 4.2).

 

(-22°F to 50°F)

(14°F)

 

 

 

 

 

 

 

 

 

 

6

Balance point high

 

-5°C to 30°C

5°C

Set the bP H value (see section 4.2).

 

(23°F to 86°F)

(41°F)

 

 

 

 

 

 

 

 

 

 

7

Defrost point

 

-10°C to 15°C

10°C

During defrost, auxiliary heating is activated when the outside

 

(14°F to 59°F)

(50°F)

temperature is below the defrost point (see section 4.3).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set according to the type of heat pump installation (see section

 

 

 

 

 

4.4).

 

 

 

 

 

Ad (add-on): Use this setting when the indoor coils are located

8

Installation type

 

Ad / nr

Ad

downstream of the auxiliary heat source. This is generally the

 

case for add-on installations.

 

 

 

 

 

 

 

 

 

 

nr (normal): Select this setting when the indoor coils are located

 

 

 

 

 

upstream of the auxiliary heat source. This is generally the case

 

 

 

 

 

for new installations.

 

 

 

 

 

 

9

Cycles per hour

 

2 to 6

4

Allows you to select the number of cycles per hour. It is recom-

 

mended to use the default setting except in exceptional cases.

 

 

 

 

 

 

 

 

 

 

 

10

“Smart fan”

 

On / OF

OF

On: “Smart fan” is On (see section 4.5).

 

OF: “Smart fan” is Off.

 

 

 

 

 

 

 

 

 

 

 

11

Interstage delay

 

5 to 90 min.

10 min.

Set the interstage delay (see section 4.6).

 

 

 

 

 

 

 

 

 

 

 

HE (heat): The humidifier can operate only when heating is acti-

 

Humidifier

 

 

 

vated.

12

 

HE / Fn

HE

Fn (fan): The humidifier can operate as long as the fan is run-

operating mode

 

 

 

 

 

ning, whether heating is activated or not.

 

 

 

 

 

 

 

 

 

 

NOTE: The humidifier is disabled when cooling is activated.

 

 

 

 

 

 

NOTE: Only items 1 to 4 are available when the controller is placed in user mode (SW2 switch).