Aube Technologies TI035 manual Installation and User Guide, n Applications, o Installation

Models: TI035

1 4
Download 4 pages 60 Kb
Page 1
Image 1
nApplications

nApplications

The TI035 programmable wall switch has been designed to control lightings and motors:

Load type

Maximum load

Examples

 

 

 

 

 

2400 W

incandescent lights

Resistive load

halogen lights

(20 A @ 120 V)

 

block heater

 

 

 

 

 

 

 

 

fluorescent lights

Inductive load

2400 W

compact fluorescent lights (CFL)

(20 A @ 120 V)

sodium lamps

 

 

 

electronic ballasts

 

 

 

 

Motor

1 hp

pool filter pumps

fans

 

 

 

 

 

 

oInstallation

NOTE: This switch cannot be used if there are not at least 2 white wires joined by a connector inside the electrical box.

nCut power at the circuit breaker to avoid electric shock. o Remove the existing switch.

p Install the new switch as shown in the diagram below. q Apply power at the circuit breaker.

black white

blue

black

white

white (neutral)

120 VAC black (line)

TI035

Installation and User Guide

Programmable Wall Switch

Manual Mode

The programmable switch operates as a regular switch. Briefly press the switch door to turn the lights On or Off. The mode (MAN) and state (ON or OFF) are displayed.

Automatic Mode

The programmable switch follows the programmed

schedule. The mode (AUTO), state (ON or OFF) and current program number are displayed. To temporarily override the programmed schedule, briefly

press the switch door. The new state (ON or OFF) will flash

to show that the state is temporary. The override remains in effect until you press the switch door again or until the beginning of the next program.

rSetting the Clock

NOTE: The switch displays the time in 24-hour format by default or following a reset.

nTo switch between 12-hour format and 24-hour format, proceed as follows:

a)Press one of the control buttons to ensure the MAN or AUTO indica- tor is displayed.

b)Press the MIN and HOUR buttons simultaneously and brieftly (0:00 display = 24-hour; 12:00 display = 12-hour ).

oSet the time using the HOUR and MIN buttons. For the 12-hour time format, if you are setting an afternoon time, ensure PM appears on the screen.

pPress one of the control buttons or close the switch door to return to normal operation.

sDaylight Savings Time

This procedure sets the switch for daylight savings time or for standard time.

nPress the CODE button four times.

oPress the MIN button to switch between nor and Ad.

nor

Standard time / Normal time / Winter time

 

 

Ad

Daylight savings time / Advanced time / Summer time

 

 

pPress one of the control buttons or close the switch door to return to nor- mal operation.

pPower-on

nPry the switch door open from the bottom using a small screwdriver.

oEnsure the ON/OFF selector is set to ON.

pReset the switch using a paper clip. 0:00

will flash.

If the display is blank:

Ensure the ON/OFF selector is properly engaged in the ON position. Push it to the right using a small screwdriver.

Reset

oInstallationTI035 Control (4)

Installation and User GuideProgrammable Wall SwitchrSetting the ClocksDaylight Savings TimepPower-on On/Off tSunset/Sunrise Program7.1Determining the sunset/sunrise parametersqOperating ModesManual backgroundManual backgroundManual backgroundManual background selector

tSunset/Sunrise Program

NOTE: By default, once you have programmed the sunset/sunrise parameters, the timer will follow the sunrise/sunset program when placed in Automatic mode. To set your own schedule, see section 8.

7.1Determining the sunset/sunrise parameters

Fill out the following table:

Latitude

Longitude

Day #

nor/Ad

Lc

 

 

 

 

 

 

 

 

 

 

1) LATITUDE & LONGITUDE: Enter the coordinates of your city or the

nearest city using the supplied table. If none of the cities in the table is appli-

qOperating Modes

The programmable switch has 2 operating modes: manual (MAN) and automatic (AUTO). To switch mode, press the switch door for 3 seconds.

cable, this information is usually available on the internet.

NOTE: Add a minus sign when entering a south latitude coordinate or a west

longitude coordinate.

TI035

400-035-001-C

13/3/07

1/2

Page 1