Negative Switched Dome Lighting

Negative Switched Dome Lighting

 

 

Red / black - Lamp on

 

 

 

 

 

 

 

 

 

 

To 12 pin

 

Black / red - Lamp common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector

 

Purple / brown - Lamp Auto

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To

constant

To

constant

Factory Door ajar switch or Body Control computer

Troubleshooting:

SYMPTOM:

REMEDY:

No power at Video Monitor

Verufy +12 VDC on Red wire at 2 pin Power Harness behind video

 

monitor. Verify ground connection with continuity test from known good

 

ground to black wire at 2 pin Power Harness

Power but no video or sound

Verify that the correct source is selected (i.e.: 1,2,3 or 4). Verify that the

 

source is on and playing a known good media (such as a videotape).

 

Verify connections at both ends of the source component harness.

Static on TV Stations

Press Auto Program button. Then press CH up or CH down. Verify

(Tuner Version Only)

antenna mounting and connections to the tuner.

 

Note: Due to the nature of TV signals, vehicle motion, direction the

 

vehicle is facing, distance from the transmitter, nearby surroundings and

 

weather may adversely affect TV reception. These conditions may result

 

in the following: picture roll, "snowy" picture, or momentary loss of color.

No Infrared remote functions

Check batteries in the hand held remote (not included with this kit). Verify

for VCP (or other components) that the IR LED ( page 7 Wiring Diagram) is properly attached to the sensor window of the VCP (or other component).