3-Wire Power Cord Installation

3-Wire Power Cord Installation

 

Remove the Terminal Block Access Plate on the back

 

of the range by removing the 2 fixing screws.

Screws

Assemble the strain relief in the hole on bracket.

 

Insert the power cord through the strain relief and

 

tighten.

 

Allow enough slack to easily attach the cord terminals

 

to the terminal block.

 

Remove the 3 wire terminal nuts and washers from

Terminal Block

the terminal block.

Access Plate

Plug the terminal holes of power cord. The neutral or

 

ground wire of the power cord must be connected to

 

the neutral terminal located in the center of the

Ground Strap

terminal block. The power leads must be connected to

 

the outside terminals.

Terminal Block

Plug washers and tighten nuts securely.

 

Assemble the Terminal Block Access Plate.

Neutral Wire

 

Power Wires

 

Power Cord

 

Bracket

4-Wire Power Cord Installation

 

Remove the Terminal Block Access Plate on the back

Grounding Screw

of the range by removing the 2 fixing screws.

Terminal Block

Assemble the strain relief in the hole on bracket.

Neutral Wire

Insert the power cord through the strain relief and

Grounding Wire

tighten.

 

Allow enough slack to easily attach the cord terminals

Power Wires

to the terminal block.

Power Cord

Remove the 3 wire terminal nuts and washers from

Bracket

the terminal block.

 

Remove the ground strap from the frame of the range and terminal by removing its screw and cutting is as shown.

Plug the terminal holes of the power cord. The neutral wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The ground wire of the power supply cord must be attached to the frame of the range by using the green colored grounding screw. The power leads must be connected to the outside terminals.

Plug washers and tighten nuts securely.

Assemble the Terminal Block Access Plate.

¾LEVELING THE RANGE

The range must be level in order to operate properly. The four leveling legs located on the corners at the bottom of range should be adjusted by turning them clockwise to make the range higher or counter- clockwise to lower the range until the range is level. Use a level on surface units to check the leveling of the range.

16

Page 16
Image 16
Avanti ER2001G, ER2401G instruction manual WirePower Cord Installation, ¾LEVELING THE RANGE