REPLACING THE OVEN LIGHT

Let the oven cavity and broil burner cool down.

Switch off the electric supply.

Remove the protective cover.

Unscrew and replace the bulb with a new one suitable for high temperature (200°~ 500°F) having the same specifications: 120V 60Hz, 15W, E14.

Replace the protective cover.

NOTE: Oven bulb replacement is not covered by your guarantee.

LEVELING THE RANGE

The range must be level to obtain proper operating. The four screws type leveling legs located on the corners at the bottom of range should be adjusted by turning them clockwise to make the range higher or counter-clockwise to lower the range until the range is level. Use a level on surface units to check the leveling of the range.

ANTI-TIP BRACKET INSALLATION

To reduce the risk of tipping the range by abnormal usage or improper door loading, the range must be secured by properly installing the anti-tip device packed with the appliance.

Place the anti-tip bracket on the floor as shown figure. Anti-tip bracket can be installed on either right or left side.

Make the locations of 2 holes of ant-tip bracket on the floor.

Use a 5/16” masonry drill bit and insert plastic anchor.

Secure bracket to floor using screws supplied.

Slide appliance into position.

NOTE: If range is relocated, the bracket must be removed and installed in new location.

23

Page 23
Image 23
Avanti GR2013CSS, GR2012CB, GR2011CW manual Replacing the Oven Light, Leveling the Range, ANTI-TIP Bracket Insallation