Avaya Inc.

 

 

 

Installation and Operation

 

 

 

Model EA401

 

 

 

 

Engineering Specifications

 

Electrical Performance

 

 

 

AUDIBLE RANGE FREQUENCY RESPONSE

300 – 3400 HZ

 

 

 

 

DIALING METHOD

IEEE DTMF OR 40/60 PULSE, 10 PPS

 

 

 

 

TRANSMIT OBJECTIVE LOUDNESS RATING (TOLR)

-38 +/- 4 dB

 

 

 

 

 

RECEIVE OBJECTIVE LOUDNESS RATING (ROLR)

TYPICAL

52 +/- 4 dB

 

 

 

 

 

SIDE TONE OBJECTIVE LOUDNESS RATING (SOLR)

TYPICAL

20 +/- 3 DB

 

 

 

 

 

RINGER OUTPUT

N/A

 

 

 

 

 

FCC RINGER EQUIVALENCE

0.9 A, 1.9B

 

 

 

 

FLASH

600 MSEC TIMED DISCONNECT

 

 

 

 

REDIAL

13 DIGITS MAXIMUM

 

 

 

 

MAXIMUM LOOP

15 KFT (4,500 M) OF 22 AWG COPPER

 

 

 

 

 

Electrical Requirements

 

 

 

LINE VOLTAGE

24 – 56 VDC

 

 

 

 

LOOP CURRENT

20 - 120 MA

 

 

 

 

RINGER DETECT RELAY SENSITIVITY (OPTIONAL)

40 – 100 V, 16 – 25 HZ

 

 

 

 

CONNECTION METHOD

FACTORY SEALED WIRING THROUGH ½” CONDUIT ENTRY

 

 

 

 

FUSE

2AG 0.25 AMP 250 VOLT

 

 

 

 

 

Environmental

 

 

 

WEATHERPROOF & WATERTIGHT

ENCLOSURE NEMA 4

 

 

 

 

TEMPERATURE

-40OTO +60O C (-40OTO 140OF)

 

 

 

 

HUMIDITY

0 TO 95% RH NON CONDENSING

 

 

 

 

DUSTPROOF

¾” FLAT FLANGE DUSTPROOF JOINTS

 

 

 

 

 

Mechanical

 

 

 

HOOK SWITCH (CRADLE SWITCH) LIFE

>1 000 000 OPERATIONS

 

 

 

 

BODY CONSTRUCTION

COPPER FREE CAST ALUMINUM WITH POWDER COAT FINISH

 

 

 

 

DIMENSIONS

325 X 173 X 122 MM (12.8 X 6.8 X 4.8 INCHES)

 

 

 

 

NET WEIGHT

7.95 KG (17.5 LBS.)

 

 

 

 

HANDSET MATERIAL

HIGH IMPACT ABS

 

 

 

 

HANDSET CORD

3.0 M (10 FT) FIELD REPLACEABLE WITH LOW TEMPERATURE

 

 

POLYURETHANE JACKET

 

MICROPHONE

DYNAMIC

 

 

 

 

 