12 Cyclades ACS 6000 Advanced Console Server Command Reference Guide
show/ls
Show the available directories, commands or parameters at the current location.
Syntax:
--:- units cli-> show
-or-
--:- units cli-> ls
Example:
--:- units cli-> show user_profile
user_profile
change_password/
--:- units cli->
power_cycle, power_off and power_on
Control power on a server connected to the serial port or outlets on a PDU that is either connected
to a serial port or to the AUX/Modem port from the Topology level when the port is enabled and
configured with the Power Profile.
NOTE: Only one outlet can be managed with the commands at this level.
Syntax:
--:- units cli-> cd topology/<PDU_ID>/outlets/
--:- outlets cli-> [power_cycle|power_off|power_on] <outlet_name>
Example:
--:- units cli-> cd topology/14-35-60P15_1/outlets
--:- outlets cli-> power_cycle 14-35-60P15_1_8
Selected outlet(s) will be switched ON after this operation. Are you
sure you want to power cycle the selected outlet(s)? y/n : y
cycle, on, off, lock and unlock
Control power on outlets on a PDU that is either connected to a serial port or to the AUX/Modem
port from the power_management level when the port is enabled and configured with the Power
Profile.
NOTE: Lock and unlock commands are only supported on Cyclades PDUs.
NOTE: Enter commas (,) between multiple outlet numbers. Using a hyphen (-) to specify a range is not
supported in CLI power management.