54 Cyclades ACS 6000 Advanced Console Server Command Reference Guide
--:- active_sessions cli-> kill 37
Power Management Options
The Power Management Options are described in Table 4.5.
To rename a PDU:
1. Log onto the CLI as an administrator and enter cd power_management/settings to navigate
to the settings level.
--:- units cli-> cd power_management/settings
2. Type rename and press Tab Tab to expand the parameters.
--:- settings cli-> rename <PDU_ID> <Tab><Tab>
3. Enter set newpdu_id=<new_PDU_ID>.
--:#- [settings] cli-> set new_pdu_id=mypdu
--:#- [settings] save
NOTE: See the Cyclades ACS 6000 Installation/Administration/User guide for how to perform other authorized
PDU configuration options.
To manage power for a selected outlet:
See cycle, on, off, lock and unlock on page 12 for how to manage power at the power_management
level.
Table 4.5: Power Management Options Descriptions
Option Description
settings Allows an authorized user to reboot, restore factory default settings or to rename
PDU(s). Also allows the authorized user to view information about each PDU, monitor
sensors, clear sensor values, set up syslogging of events related to the PDU,
configure an alarm and the LED display mode, and to manage outlets on the PDU.
management Shows a list of PDUs, including PDU ID, Vendor and Model Number of Outlets
Position. Allows user to turn on, turn off, cycle or reboot the PDUs.
outlet_groups Lists all configured outlet groups that the current user is authorized to manage (to
manage outlet groups, the user must be in a user group that is authorized to manage
all the outlets in the outlet group).