AXIS 241Q/241S - System Options 45

Ports & Devices

I/O Ports - the pinout, interface support and the control and monitoring functions provided by this connector are described in Unit Connectors, on page 48.

Maintenance

Restart - The unit is restarted without changing any of the settings. Use this method if the unit is not behaving as expected.

Restore - The unit is restarted and most current settings are reset to factory default val- ues. The settings that will not be reset are as follows:

the boot protocol (DHCP or static)

the static IP address

the default router

the subnet mask

the system time

Default - The default button should be used with caution. Pressing this will return all of the video server's settings to the factory default values (including the IP address)

Upgrade Server - See Upgrading the Firmware, on page 52.

Backup - To take a backup of all of the parameters, and any user-defined scripts, click this button. If necessary, it is then possible to return to a previous configuration if settings are changed and there is unexpected behavior.

Restore - click the Browse button to locate the saved backup file (see above) and then click the Restore button. The settings will be restored to the previous configuration.

Note: Backup and Restore can only be used on the same unit running the same firmware. This feature is not intended for multi-configurations or for firmware upgrades.