AXIS P33/P33-V Network Camera Series Installation Guide

Page 15

Adjust the Lens

Horizontal line

Tilt adjustment screw

 

Tilt adjustment screw

Locking screw

 

Open the Live View page in the web interface and make the following adjustments to the camera:

1.Loosen the locking screw and tilt adjustment screws.

2.Turn the lens (with the lens holder) to the desired position. Make sure the horizontal lines on either side of the lens are aligned horizontally.

Note: Ensure that the mark on the lens cover, between the horizontal lines, is facing up.

3.Once satisfied, gently tighten the locking screw and tilt adjustment screws to secure the camera’s position.

4.Open the Focus Adjustment page in the Web interface under Setup > Basic Setup > Focus & Zoom, and follow the on-screen instructions. Use the image window to adjust the focus and zoom. See the online help files for more information.

Note: Due to the dome’s refraction, the image may appear slightly out of focus once the dome has been placed. To correct this go to the Focus Adjustment page in the Web interface under Setup > Basic Setup > Focus & Zoom, and adjust the focus again.

Warning! Adjusting the focus and zoom manually can damage the lens.

ENGLISH

Page 15
Image 15
Axis Communications P3346-V manual Adjust the Lens, Axis P33/P33-V Network Camera Series Installation Guide