AXIS P5415–E PTZ Dome Network Camera

Technical Specifications

Function/group

Item

Specifications

 

 

 

 

Operating

Temperature: –20 °C to 50 °C (–4 °F to 122 °F)

 

conditions

Humidity 10–100% RH (condensing)

 

 

 

 

Approvals

EN 50121–4, IEC 62236–4, EN 55022 Class B, EN 61000-6-1, EN 61000-6-2,

 

 

EN 55024, FCC Part 15 Subpart B Class B, ICES-003 Class B, VCCI Class B,

 

 

C-tick AS/NZS CISPR 22 Class B, KCC KN22 Class B, KN24, IEC/EN/UL 60950-1,

 

 

IEC/EN/UL 60950-22, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-14,

 

 

IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 IP66, EN 50581,

 

 

NEMA 250 Type 4X, ISO 4892-2

 

 

 

 

Weight

3.5 kg (7.7 lb)

 

 

 

 

Included

Installation Guide, AVHS Authentication key, installation and management software CD,

 

accessories

Windows decoder 1–user license

 

 

 

 

Video

AXIS Camera Companion (included), AXIS Camera Station and video management

 

management

software from Axis’ Application Development Partners (not included). For more

 

software (sold

information, see www.axis.com/products/video/software

 

separately)

 

 

Optional

AXIS P54 Smoked dome

 

accessories

T8123 High PoE-30W Midspan 1-port

 

 

AXIS T94P01B Corner Bracket

 

 

AXIS T8310 Video Surveillance Control Board

 

 

AXIS T90A Illuminators

 

 

AXIS High PoE midspans

 

 

Installation Display

 

 

Multi-user decoder license pack

 

 

 

Connectors

I/O Terminal Connector

6–pin terminal block for:

• Digital Input

• Digital Output

• 0 V DC (-)

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

0 V DC

 

 

 

 

DC output

2

Can be used to power auxiliary equipment.

12 V DC Power

 

 

Note: This pin can only be used as power out.

Max load = 50 mA

 

 

 

 

Configurable

3–6

Digital input – Connect to pin 1 to activate, or leave floating

0 to +30 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

 

 

 

 

Digital output – Connected to pin 1 when activated, floating

Max load = 100 mA

 

 

(unconnected) when deactivated. If used with an inductive

Max voltage = +30 V DC

 

 

load, e.g. a relay, a diode must be connected in parallel with

 

 

 

the load, for protection against voltage transients.

 

 

 

 

 

65