With 2-wire RS-485 mode operation, your connection cable must
jumper TD(A) to RD(A) and TD(B) to RD(B). Connect from TD(A)
and TD(B) to the Data A(
) and Data B(+) wires of your RS-485
network.
See Chapter 6 for example connections.
Note that the EIA RS-422 Specification labels data lines with an "A"
and "B" designator. Some RS-422 equipment uses a "" and "+"
designator. In almost all cases, the "A" line is the equivalent of the
"" line and the "B" line is the equivalent of the "+" line.
Moreinformation on RS-422 communications can be found in the B&BElectronics RS-422/485 Application Note (available on ourwebsite)
.
Table B.3: RS-422/485 Pinouts
Name Description Direction DB9M
Pin
RD(A)
Receive Data A Input 1
TD(B) + Transmit Data B Output 2
TD(A)
Transmit Data A Output 3
GND Signal Ground ------ 5
RD(B) + ReceiveData B Input 9