The RS-485 mode is set using 3 jumpers per port, and by selecting
the RS-485 Mode for DTR Operation on that com port.
RS-485 Network Biasing
In an RS-485 network, the transmitter tri-states to a high impedance
state. Unlike RS-422 where the transmitter holds the TD(B) line high
and the TD(A) line low (Mark state) when not transmitting data.
To establish and maintain the Mark state for all RS-485 receivers,
Biasing is required. Biasing maintains a positive voltage difference
from RD(B) relative to RD(A) above the receiver threshold of 200mV
for all devices on that section of the network. If the biasing is not
maintained, the first data bit of a signal may not be detected, and
one or more devices may not respond to commands, or may operate
intermittently.
The RS-485 receivers on the 3PCI2 are biased with a 4.7 Kpull-up
resistor on the Receive Data B line and a 4.7 Kpull-down resistor
on the Receive Data A line. These values are usually adequate for
networks without termination and 31 or fewer nodes. When
termination is used, biasing must be increased, calculated according
to the termination value and number of nodes. Through-hole pads
are provided for adding smaller value pull-up and pull-down
resistors.
Port 1 (Low: R2/14, Hi: R3/13) R2 = R3 = 4.7K
Port 2 (Low: R4/16, Hi: R5/17) R4 = R5 = 4.7K
Combination of termination and bias must not fall below 54 Ohms.
Termination: Not installed. Not required for baud rates 19.2K or
less.
Port 1 (R15) , Port 2 (R18) R15/R18 • 120 ohms120 ohms