This barrier has been completely assembled and test run through 24

 

complete cycles under full power at the factory. If satisfactory

 

operation is not displayed in step #7, recheck all electrical connections

 

carefully. CONSULT FACTORY IF PROBLEM IS NOT FOUND.

8.Remove side arm tube cover plate (Item #2). Locate pillow block bearings (Item #12). Do not tighten set screws. Now center assembly with housing. When assembly is correctly centered, tighten bearing set screws.

9.Insert arm, with endlock intact, into the main arm tube base. Push tube far enough to make the cable, connections at the pivot. After cables have been securely bolted to the pivot mechanism, extend arm so that the endlock saddles satisfactorily over the anchor assembly (on the bollard). Slide lock coller into place and tighten allen bolts.

NOTE 6: If endlock fails to line up properly, loosen bearing bolts and rotate laterally. Re-tighten bolts. Now tighten arm base bolts securely. Replace side arm tube cover plate (tighten bolts securely).

10.With the arm in the down position, install the allotted amount of counterweights (Item #3) on the side arm tube assembly. Tighten bolts securely.

11.Close the main disconnect switch (S1) and operate the control circuit. If all connections are made correct, barrier arm will operate to fully up or fully down. The limit switch will automatically stop the motor at the extreme 90-degree movement of the arm.

12.With the barrier in the lowered position, check endlock mechanism for any type of hindrance with bollard post and adjust accordingly if required.

IMPORTANT: IF THREE PHASE POWERE CONNECTIONS TO THE MOTOR ARE REVERSED, THE LIMIT SWITCH WILL AUTOMATICALLY DISCONNECT THE MOTOR WHEN THE DRIVE CRANK HAS ROTATED ABOUT 30 DEGREES IN THE INCORRECT DIRECTION, DEPENDING ON THE POSITION OF THE CONTROLS, i.e., UP OR DOWN. DRIVE CRANK MUST THEN ROTATE BACK TO ORIGINAL (VERTICAL) POSITION USING HANDCRANK, IN ORDER TO RESET BARRIER.

If this problem occurs, phase must be reversed. The limit switch has been set at the factory and should NOT REQUIRE ADJUSTMENT. Arm should be raised or lowered by lengthening or shortening of the connecting rod not by adjustment of the limit switch cams.

© 2007 B&B ARMR

WWW.BB-ARMR.COM

(800) 367-0387

Page 6
Image 6
B&B Electronics CR-25E manual Carefully. Consult Factory if Problem is not Found

CR-25E specifications

B&B Electronics CR-25E is a robust and versatile device designed for fulfilling the needs of industrial communication systems. Characterized by its reliability and advanced functionality, the CR-25E is widely recognized in the automation and control sectors.

One of the key features of the CR-25E is its high-speed data transmission capabilities. With support for both RS-232 and RS-485 communication protocols, the device ensures seamless integration across various systems. The CR-25E operates at speeds up to 115.2 Kbps, allowing for rapid data exchange, which is crucial in applications like robotic controls, sensors, and monitoring systems.

Another standout characteristic of the CR-25E is its built-in isolation features. With 2.5 kV isolation on the serial lines, it protects the connected equipment from voltage spikes and noise, significantly enhancing the reliability of the communication link. This isolation effectiveness is particularly valuable in environments rife with electrical interference, as it ensures stable operation and long-lasting performance.

The CR-25E supports multiple power input options, including AC and DC power supplies. This flexibility enables easy integration into existing systems without the need for extensive modifications or additional components. The device also features wide input voltage ranges, thus accommodating different industrial environments and requirements.

In terms of mounting options, the CR-25E is designed with user-friendliness in mind. The compact design and DIN rail compatibility facilitate easy installation in control panels, maximizing space efficiency while maintaining accessible connectivity for maintenance or troubleshooting.

For monitoring and configuration, the CR-25E integrates effortlessly with various industrial software and applications. The device features diagnostic LEDs to provide real-time indications of operational status, simplifying troubleshooting by allowing users to quickly identify issues.

In summary, B&B Electronics CR-25E stands out due to its high-speed data transmission, robust isolation features, versatile power input capabilities, and user-friendly design. These attributes make it a preferred choice among engineers and technicians in the field of industrial communication, ensuring that systems remain efficient, reliable, and effective in demanding operational settings.