Z2 Product ID - Each message transmitted from your remote includes a Product Code, identifying the
manufacturer, and a product ID code from 1 to 16. The product ID code allows multiple B&K products to be
controlled f rom the s ame rem ote. Your receiver actually uses two product ID codes - one for zone 1 (normally set
to ID code 1) and the other for zone 2 (normally set to ID code 2). If you have a system with m ultiple B&K products
then you m ay wish to s et the product ID c odes to other values. Note that you cannot set the Z1 product ID to the
same setting as zone 2 or vice versa. If you need to set zone 2 to the current zone 1 setting then set zone 1 to
some other value first. Make sure you are in the ADVANCED ZONE SETTINGS menu and the remote is in AUDIO
mode.
WARNING - If you change the product ID code in the receiver without making the corresponding change
to the remote then the remote will no longer work. Refer to the separate remote manual for details on
changing the remote’s product ID (“device code”).
ADVANCED 2 ZONE SETTINGS
2 Z2 Max Level +15dB
3 Z2 Product ID 2
move to new line
p
revious
p
a
g
e
↑ ↓
MENU
4 V2 Output Tape
1 Z2 Level Control Variable
ad
j
ust
p
arameter
←→
WARNING Connectin
g
a ta
p
e
recorder to V2 in LINE mode
can cause s
p
eaker dama
g
e
set desired product IDVOLUME KNOB
(REW) or(FF)
2
move to Zone 2 Zone ID
(UP) or (DOWN)
(PAUSE) or (STOP)
1
ActionFrom Front PanelFrom Remote
V2 Output - V2 output is normally set up as a tape loop. The V2 and Z2 output are the current source (V1,
TV-V3, CD, DVD, etc .) ex c ept when the current selec tion is V2. When V2 is selected as the s ourc e, the Z2 output
is V2 and the V2 output is the previously selected sourc e. This prevents feedbac k when the V2 inputs and outputs
are connected to a tape deck or VCR. Feedback can cause high frequency oscillations which may damage your
speak ers. If you don’t connect a tape deck to the V2 input and output you can use the V2 output as an additional
line out. In this mode V2 output is always the selected input including V2.
ADVANCED 2 ZONE SETTINGS
2 Z2 Max Level +15dB
3 Z2 Product ID 2
move to new line
p
revious
p
a
g
e
↑ ↓
MENU
4 V2 Output Tape
1 Z2 Level Control Variable
ad
j
ust
p
arameter
←→
WARNING Connectin
g
a ta
p
e
recorder to V2 in LINE mode
can cause s
p
eaker dama
g
e
move back to ADVANCED SYSTEM SETUP MENUMENU3
select either Tape or LineVOLUME KNOB
(REW) or(FF)
2
move to V2 Output
(UP) or (DOWN)
(PAUSE) or (STOP)
1
ActionFrom Front PanelFrom Remote
45 p/n 12699 Rev. 9812C