Set-Up Mode

The printer has been set up at the factory with the following default parameters:

Baud rate

: 9600 bps

Handshaking

: DTR

Country

: U.S.A.

Print mode

: Text (upright)

Paper

: Normal paper

IrDA

: IrDA-SIR

If necessary, the default parameters can be changed as follows:

1.With the printer initially switched OFF, press and hold down the SEL pushbutton; then switch the printer ON.

2.The printer now goes into its set-up mode and prints its current parameter status. Observe that the green Power LED flashes to indicate that the printer is in its set-up mode.

Note: If no pushbuttons are pressed within 15 seconds, the set-up mode is automatically terminated without changing the original parameters.

3.Baud rate is first parameter printed. Pressing the FEED button causes the value of that parameter to change in the sequence shown in the following table.

SEL Button

 

FEED Button

 

 

 

 

Baud rate

 

2400, 4800, 9600, 19200, 38400, 57600, 115200

Handshaking

 

DTR, X-on/X-off

Country

 

U.S.A., Korea, Cyrillic, Denmark2, Norway,

 

 

Japanese, Spain, Italy, Sweden, Denmark1,

 

 

U.K., Germany, France

Print mode

 

Text(upright), Data(inverted)

Paper

 

Normal paper, Reprint paper

Density

 

50 – 150% in 5% steps

IrDA

 

Chamjin-Ir, IrDA-Sir, BHT-Ir(DENSO), EL-ME-Ir