Rotisserie Ventless Hood | Maintenance |
|
|
Maintenance
Electrocution could occur if this unit is hosed down with water. This unit is NOT designed for hose
Electrocution could occur if power is not removed from this unit before servicing. Remove power at disconnect or circuit breaker BEFORE servicing hood.
Scheduled Maintenance
Use the following table to help manage scheduled maintenance activities.
FREQUENCY | PERFORMED BY | PART | ACTIVITY |
|
|
|
|
Daily | User | Entire Hood | Wipe unit down with a soft rag and mild |
|
|
| cleaning agent. |
|
|
|
|
| User | Condensation | Check condensation trough. Empty if |
|
| trough | necessary. |
|
|
|
|
| User | Grease Baffle | Clean grease baffle. If necessary, refer |
|
|
| to the procedure in this manual for |
|
|
| cleaning the baffle. |
|
|
|
|
Weekly | User | Charcoal/Odor Filter | Inspect charcoal/odor filter. In low to |
|
|
| medium volume applications, the filter |
|
|
| may need replacement prior to the |
|
|
| indicating light turning on. This |
|
|
| condition will be evident by a strong |
|
|
| odor coming from the face of the filter. |
|
|
| If necessary, refer to the procedure in |
|
|
| this manual for replacing the filter. |
|
|
|
|
Monthly | User | Door and Filter | Check door and filter interlock |
|
| Interlock | operation. The unit should not operate |
|
|
| with the front door open or either the |
|
|
| grease baffle or charcoal/odor filter |
|
|
| removed. Clean area between grease |
|
|
| baffle and charcoal/odor filter. |
|
|
|
|
Injury from rotating fan blades could occur if power is not removed from this unit before cleaning the blower section. Remove power at disconnect or circuit breaker BEFORE cleaning the blower section.
3 Months
User
Blower Section
Clean the blower section.
12