Operation

Operator Control Panel

The Operator Control Panel is shown in Figure 4-1.

Figure 4-1 Operator Control Panel

Oil Level

Auto Power Save Switch

Lamp

 

 

Multi Monitor Display

Units LED’s

~ AC OUTPUT

Units

Select

Switch

STOP

 

NEMA 5−20R

DC

STOP

Breaker

 

 

 

 

ON

 

ON

 

 

 

START

 

 

CHOKE

+

 

 

 

NEMA L530R

+

BATTERY CHARGE ONLY

DC 12V − 8.3A

Auto

Engine

Key

(−) Battery Charger

(+) Battery Charger

Ground

P−Save LED

Switch

Switch

Connection

Connection

Terminal

Multi Monitor Display

A five digit display for messages or display of Hours, Volts or Hertz.

 

Overload Display

“O_LOD” is displayed on the Multi Monitor display when generator is running and an

 

 

overload condition exists. To reset, Stop the generator and Start the generator again to

 

 

resume operation.

 

 

Units LED’s

 

When Units Select Switch is set to Hours, Units Hours LED is ON and

 

 

 

 

operating hours is displayed on Multi Monitor Display.

 

 

 

When Units Select Switch is set to V, Units V LED is ON and

 

 

 

 

Generator Output Volts is displayed on Multi Monitor Display.

 

 

 

When Units Select Switch is set to Hz, Units Hz LED is ON and

 

 

 

 

Generator Output Frequency is displayed on Multi Monitor Display.

Units Select Switch

Pressing

Switch changes display modes from Hours, Volts and Hz.

 

Oil Level Lamp

Lamp is on when engine oil level is less than a predetermined level. When the lamp

 

 

turns ON, the engine will stop automatically. If Oil Lamp is ON, replenish the engine oil

 

 

level and restart the engine.

 

 

Auto Power Save Switch Press Manual background to select Power Save Mode, (Auto P−Save LED is ON) and generator speed changes for the applied load. Output voltage and frequency remain constant even at engine idle speed.

Press Manual background again to deselect Power Save mode and generator runs at full speed and produces full power. Use this mode (Auto P−Save LED is OFF) for DC power.

Auto P−Save LED

OFF when generator runs at full speed and produces full power.

 

ON when generator is in Power Save Mode (Adjustable Speed).

Engine Switch

Stop

In this position, the engine is stopped and fuel supply line is closed.

 

Run

Allows the engine to start and run during normal operation.

 

Choke

Allows cold weather starting, place the Engine Switch in the Run position

 

 

after engine is started.

Key Switch

Stop

In this position, the engine is stopped.

 

ON

Engine run position after starting.

 

Start

Engine start position, engages engine starter to crank the engine.

MN2403

Operation 4-1