Section 4
Operation
Operator Control Panel
The Operator Control Panel is shown in Figure
Figure
Oil Level | Auto Power Save Switch | ||
Lamp | |||
|
| ||
Multi Monitor Display | Units LED’s |
~ AC OUTPUT
Units
Select
Switch
STOP |
| NEMA 5−20R | DC | |
STOP | Breaker | |||
| ||||
|
|
| ||
ON |
| ON |
| |
|
| START |
| |
| CHOKE | − | − + | |
|
|
|
NEMA L530R
+
BATTERY CHARGE ONLY
DC 12V − 8.3A
Auto | Engine | Key | (−) Battery Charger | (+) Battery Charger | Ground |
P−Save LED | Switch | Switch | Connection | Connection | Terminal |
Multi Monitor Display | A five digit display for messages or display of Hours, Volts or Hertz. |
| |||
Overload Display | “O_LOD” is displayed on the Multi Monitor display when generator is running and an | ||||
|
| overload condition exists. To reset, Stop the generator and Start the generator again to | |||
|
| resume operation. |
|
| |
Units LED’s |
| When Units Select Switch is set to Hours, Units Hours LED is ON and |
| ||
|
|
| operating hours is displayed on Multi Monitor Display. |
| |
|
| When Units Select Switch is set to V, Units V LED is ON and |
| ||
|
|
| Generator Output Volts is displayed on Multi Monitor Display. |
| |
|
| When Units Select Switch is set to Hz, Units Hz LED is ON and |
| ||
|
|
| Generator Output Frequency is displayed on Multi Monitor Display. | ||
Units Select Switch | Pressing | Switch changes display modes from Hours, Volts and Hz. |
| ||
Oil Level Lamp | Lamp is on when engine oil level is less than a predetermined level. When the lamp | ||||
|
| turns ON, the engine will stop automatically. If Oil Lamp is ON, replenish the engine oil | |||
|
| level and restart the engine. |
|
|
Auto Power Save Switch Press to select Power Save Mode, (Auto P−Save LED is ON) and generator speed changes for the applied load. Output voltage and frequency remain constant even at engine idle speed.
Press again to deselect Power Save mode and generator runs at full speed and produces full power. Use this mode (Auto P−Save LED is OFF) for DC power.
Auto P−Save LED | OFF when generator runs at full speed and produces full power. | |
| ON when generator is in Power Save Mode (Adjustable Speed). | |
Engine Switch | Stop | In this position, the engine is stopped and fuel supply line is closed. |
| Run | Allows the engine to start and run during normal operation. |
| Choke | Allows cold weather starting, place the Engine Switch in the Run position |
|
| after engine is started. |
Key Switch | Stop | In this position, the engine is stopped. |
| ON | Engine run position after starting. |
| Start | Engine start position, engages engine starter to crank the engine. |
MN2403 | Operation |