Section 4

Section 4

Operation

Operator Control Panel

Each operator panel is slightly different, depending on features of the generator you purchased. The Operator Control Panel of Figure 4-1 is shown because it has most of the available features. This will be used to explain how the controls operate.

PCM60RE

Figure 4-1 Operator Control Panels

PCM90VE

 

 

 

120 VOLTS

120 VOLTS

 

120 VOLTS

 

CIRCUIT BREAKERS

120/240 VOLTS

CIRCUIT BREAKERS

120/240 VOLTS

Press to Reset

 

Press to Reset

 

 

 

 

AC Circuit Breakers Provide overcurrent protection for the generator output. When tripped, the plunger (in center of breaker) will extend out about 3/8 inch. Remove the loads, push the plunger into the breaker to reset the breaker the restore the loads.

WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch. The National Electrical Code (NEC) requires that connection of a generator to any elastical circuit normally powered by means of an electric utility must be connected by means of approved transfer switch equipment so as to isolate the electrical circuit from the utility distribution system when the generator is operating. Failure to isolate the electrical circuits by such means may result in injury or death to utility power workers due to backfeed of electrical energy onto the utility lines.

Receptacles – Receptacles are provided to allow easy connection of electrical loads. Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch. Multiple receptacles may be used at the same time provided the total electrical load does not exceed the generators rated output.

120Volts –

PC30H has no GFCI protection, 3 outlets rated 125VAC at 15 Amperes.

 

All others have NEMA 5–20R GFCI Duplex receptacle provides ground fault

 

protection. Rated 125VAC at 20 Amperes.

30 Amps 120 Volts –

Twist lock NEMA L5–30R receptacle, rated 125 Volts at 30 Amperes.

30 Amps 120/240 Volts – Twist lock NEMA L14–30R receptacle rated 250Volts at 30 Amperes.

Note: The nominal voltage produced by the generator at each receptacle is 120VAC or 240VAC.

MN2413

Operation 4-1