Appendix A

PowerchiefR Multifuel Series

Information in this Appendix applies to the following Baldor Generators:

PCM60RE, PCM90VE

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

Figure A-1 PCM60RE and PCM90VE Operator Panel

NEMA 5-20R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.

NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps.

NEMA L14-30R Receptacle. Twist-lock style receptacle rated for 125/250VAC, 30 Am

120 VOLTS

Circuit Breakers.

Provide overload protection for the generator set.

120 VOLTS

CIRCUIT BREAKERS

120/240 VOLTS

Press to Reset

MN2413

PowerchiefR Multifuel Series A-1

Page 27
Image 27
Baldor Series PC Mutlifuel manual Appendix a PowerchiefR Multifuel Series, Operator Panel Configuration