Extended System Commands

STX KC Get Configuration

This command returns the configuration of the printer. The form of the returned data is similar to that of a Configuration Label. This command should be parsed by KEYWORDS, not Character POSITIONS. Each line is terminated by a CR (0x0d) & LF (0x0a). Datamax will make every effort to keep Keyword consistent.

Syntax:

Printer response:

<STX>KC<CR>

XXX NOT SET 00, 0000 00:22 000

 

 

 

 

VER: E4304 - 04.06 08/24/01

ALIGN LENGTH______

460

BOOT 83-2329-04A

 

 

STOP LOCATION_____

PEEL

CODE 83-2325-04F

 

 

INPUT VALUES

 

 

 

FONT 83-2337-01A

 

 

PAPER_____________

 

0

CPLD 59-2157-01C

 

 

POT_______________ 255

INTERNAL FLASH MODULE PRESENT

TRAN______________ 250

SYSTEM RAM CHECKS____ GOOD

REFL______________

 

0

SYSTEM RAM SIZE___ 2015

KBYTES

RIBN______________ 116

SYSTEM RAM AVAIL__ 1244

KBYTES

TEMP______________

52

REG POWER SUPPLY__ YES

 

VOLT______________ 214

CONFIGURATION

 

 

COUNTER INFORMATION

 

 

DIRECT THERMAL

 

 

ABSOLUTE VALUES

 

1-

1-1995

SERIAL PORT SELECTED

 

LENGTH____

2065

INCHES

9600;8 BITS

 

 

TIME______

 

62

HOURS

EDGE

 

 

RESETABLE VALUES

 

1-

1-1995

CONT FORM LENGTH__

0

 

LENGTH____

2065

INCHES

PRESENT ADJUST____

127

 

TIME______

 

62

HOURS

SOP ADJUST________

127

 

MEMORY CONFIGURATION

 

TOF LOW___________

0

0

INTERNAL MODULE______

15

TOF DELTA_________

10

10

SCALABLE FONTS_______

32

TOF GAIN__________

12

10

LABEL SIZE

0416:02157 IN

OOS MAXVOLT_______

3

3

END OF LIST

 

 

 

LABEL ALIGNMENT___

AUTO

 

 

 

 

 

STX Kc

Set Configuration

This command, equivalent to using other system commands followed by the <SOH>U and intended for easily configuring a custom setup not dynamic configuration changes, specifies the Power-up Configuration parameter values for the printer. The printer will reset upon completion of a command stream containing parameter value (e.g., memory configuration, label width, etc.) changes; no commands should be sent until this reset is complete. The following are highlights of this command:

These parameter values do not affect the factory default settings of the printer.

When separated by a semi-colon (;), multiple parameter values included in a single command stream.

All values are stored in Flash memory and remain in effect until new values are received or until factory defaults are restored.

If system commands are sent that override the Power-up Configuration value(s), the Power-up Configuration value(s) will be restored the next time the printer is powered ‘on’ or reset.

The parameters are the same as those found in the Setup Menu.

Note: Illegal or out of range parameter values may have unpredictable results.

E-Class DPL Programmer’s Manual