Extended System Commands
STX KC Get Configuration
This command returns the configuration of the printer. The form of the returned data is similar to that of a Configuration Label. This command should be parsed by KEYWORDS, not Character POSITIONS. Each line is terminated by a CR (0x0d) & LF (0x0a). Datamax will make every effort to keep Keyword consistent.
Syntax:
Printer response:
<STX>KC<CR>
XXX NOT SET 00, 0000 00:22 000 |
|
|
|
| ||
VER: E4304 - 04.06 08/24/01 | ALIGN LENGTH______ | 460 | ||||
BOOT |
|
| STOP LOCATION_____ | PEEL | ||
CODE |
|
| INPUT VALUES |
|
|
|
FONT |
|
| PAPER_____________ |
| 0 | |
CPLD |
|
| POT_______________ 255 | |||
INTERNAL FLASH MODULE PRESENT | TRAN______________ 250 | |||||
SYSTEM RAM CHECKS____ GOOD | REFL______________ |
| 0 | |||
SYSTEM RAM SIZE___ 2015 | KBYTES | RIBN______________ 116 | ||||
SYSTEM RAM AVAIL__ 1244 | KBYTES | TEMP______________ | 52 | |||
REG POWER SUPPLY__ YES |
| VOLT______________ 214 | ||||
CONFIGURATION |
|
| COUNTER INFORMATION |
|
| |
DIRECT THERMAL |
|
| ABSOLUTE VALUES |
| 1- | |
SERIAL PORT SELECTED |
| LENGTH____ | 2065 | INCHES | ||
9600;8 BITS |
|
| TIME______ |
| 62 | HOURS |
EDGE |
|
| RESETABLE VALUES |
| 1- | |
CONT FORM LENGTH__ | 0 |
| LENGTH____ | 2065 | INCHES | |
PRESENT ADJUST____ | 127 |
| TIME______ |
| 62 | HOURS |
SOP ADJUST________ | 127 |
| MEMORY CONFIGURATION |
| ||
TOF LOW___________ | 0 | 0 | INTERNAL MODULE______ | 15 | ||
TOF DELTA_________ | 10 | 10 | SCALABLE FONTS_______ | 32 | ||
TOF GAIN__________ | 12 | 10 | LABEL SIZE | 0416:02157 IN | ||
OOS MAXVOLT_______ | 3 | 3 | END OF LIST |
|
|
|
LABEL ALIGNMENT___ | AUTO |
|
|
|
|
|
STX Kc | Set Configuration |
This command, equivalent to using other system commands followed by the <SOH>U and intended for easily configuring a custom setup not dynamic configuration changes, specifies the
•These parameter values do not affect the factory default settings of the printer.
•When separated by a
•All values are stored in Flash memory and remain in effect until new values are received or until factory defaults are restored.
•If system commands are sent that override the
•The parameters are the same as those found in the Setup Menu.
Note: Illegal or out of range parameter values may have unpredictable results.