Extended System Commands

TOF Bias / TOF Bias Reflective – Manual entry for the control of the minimum voltage required to detect the label.

TOF Delta / TOF Delta Reflective Manual entry for the control of the low level voltage difference level to recognize a label “gap” or “mark.”

TOF Gain / TOF Gain Reflective Manual entry for the control of the voltage to the LED emitter of the Media Sensor.

STX KD Database Configuration

This command, stored in Flash memory and retained for future power-ups, controls the printer’s environment and operates as a pseudo DIP switch.

Syntax:<STX>KDwxyz<CR>

Where:w, x, y, and z are binary values with respective bit settings as defined in the following tables. (Bit 0 is least significant.)

Sample:<STX>KD@H@@<CR>

The sample configures the printer as follows:

@Sets the communications to 9600 baud with an 8-bit word and no parity;

HSelects direct thermal printing, standard control characters, and enables the media cutter; @ Selects gap sensing;

@ Is the default setting (items saved for future expansion).

Note: The Ignore Host Distance setting (see below) allows the printer to disregard <STX>O and <STX>f commands; a feature provided for host system software that sends these commands with values that may be inappropriate for the printer and result in incorrect start of print and present distances. Use the <STX>KD command or the Setup Menu to enable this feature.

E-Class DPL Programmer’s Manual

33

Page 43
Image 43
Datamax E4203 manual STX KD Database Configuration, SyntaxSTXKDwxyzCR