Extended System Commands
Syntax:
Where:
Sample:
<STX>Kcaa1val1[;aaIvalI][;aanvaln]<CR>
aa1, aaI, aan - Are two letter parameter names
val1, valI, valn - Are parameter values, with ranges appropriate for the associated parameter
<STX>KcPA120;CL600;STC<CR>
The sample sets the Present Adjust to 120 dots, the Continuous Label Length to 6 inches, and the Media Sensor Type to Continuous.
The following table summarizes the different Set Configuration Command parameters. Descriptions of these parameters can be found by referencing the Command Equivalent. Where no equivalent is given, Unique parameters descriptions are given below.
Parameter | Parameter | Value | Units / | Setup | Command | ||
Menu | |||||||
Name | Pneumonic | Range | Interpretation | Equivalent | |||
Item | |||||||
|
|
|
|
|
| ||
Continuous Label Length | CL | 0 – | 9999 | 1/100 in. | 10 | <STX>c | |
Configuration Query | QQQ | none | none | N/A | N/A | ||
Control Codes | CC | S, 1, 2 | Standard, Alternate, | 9 | <STX>KD | ||
Cutter Equip | CE | Y, N | Enabled, Disabled | 4 | <STX>KD, | ||
|
|
|
|
|
| <STX>V | |
Internal Module A | IM | 0 – 128 | 4 KB | 17 | <STX>KM | ||
Label Alignment | LA | Y, N, A | Enabled, Disabled, Automatic | 18 | N/A | ||
Label Alignment Length | AL | 000 – 999 | 1/100 inch | 19 | N/A | ||
Label Width | LW | 75 - head width | 1/100 inch | 15 | <STX>KM | ||
No Paper Min (OOS) | TN | 0 | – 16 | .1 Volt DC | 11 | N/A | |
No Paper Min Reflective | RN | 0 | – 16 | .1 Volt DC | 11 | N/A | |
Print Method | MT | D, T | Direct, Thermal Transfer | 1 | <STX>KD | ||
Present Adjust | PA | 0 – 255 | Dots | 6 | N/A | ||
Present Sensor Enable | PS | Y, N | Enabled, Disabled | 3 | <STX>KD, | ||
|
|
|
|
|
| <STX>V | |
Scalable Cache | SC | 0 – 128 | 4 KB (0 = disabled) | 16 | <STX>KS | ||
Sensor Type | ST | G, C, R | Gap (Edge), Continuous, | 2 | <STX>e, | ||
|
|
|
| Reflective |
| <STX>r, | |
|
|
|
|
|
| <STX>KD | |
Serial Port Configuration | SP |
| A | See details below | 7, 8 | <STX>KD | |
SOP Adjust | SA | 0 – 255 | Dots | 5 | N/A | ||
Stop Location | SL | H, P, C, T, N | Host, Peel, Cut, Cover, None | 20 | N/A | ||
TOF Bias | TB | 0 | – 50 | .1 Volt DC | 14 | N/A | |
TOF Bias Reflective | RB | 0 | – 50 | .1 Volt DC | 14 | N/A | |
TOF Delta | TD | 0 | – 50 | .1 Volt DC | 13 | N/A | |
TOF Delta Reflective | RD | 0 | – 50 | .1 Volt DC | 13 | N/A | |
TOF Gain | TG | 0 | – 15 | .1 Volt DC | 12 | N/A | |
TOF Gain Reflective | RG | 0 | – 15 | .1 Volt DC | 12 | N/A |
Table 5-2: Set Configuration Commands
Configuration Query – This command causes the printer to respond with the current configuration settings. The <STX>Kc response command stream format is sent to the host
30 |