Datamax E4203 manual STXKcaa1val1aaIvalIaanvalnCR, Set Configuration Commands

Models: E4203

1 176
Download 176 pages 49.58 Kb
Page 40
Image 40

Extended System Commands

Syntax:

Where:

Sample:

<STX>Kcaa1val1[;aaIvalI][;aanvaln]<CR>

aa1, aaI, aan - Are two letter parameter names

val1, valI, valn - Are parameter values, with ranges appropriate for the associated parameter

<STX>KcPA120;CL600;STC<CR>

The sample sets the Present Adjust to 120 dots, the Continuous Label Length to 6 inches, and the Media Sensor Type to Continuous.

The following table summarizes the different Set Configuration Command parameters. Descriptions of these parameters can be found by referencing the Command Equivalent. Where no equivalent is given, Unique parameters descriptions are given below.

Parameter

Parameter

Value

Units /

Setup

Command

Menu

Name

Pneumonic

Range

Interpretation

Equivalent

Item

 

 

 

 

 

 

Continuous Label Length

CL

0 –

9999

1/100 in.

10

<STX>c

Configuration Query

QQQ

none

none

N/A

N/A

Control Codes

CC

S, 1, 2

Standard, Alternate, Alternate-2

9

<STX>KD

Cutter Equip

CE

Y, N

Enabled, Disabled

4

<STX>KD,

 

 

 

 

 

 

<STX>V

Internal Module A

IM

0 – 128

4 KB

17

<STX>KM

Label Alignment

LA

Y, N, A

Enabled, Disabled, Automatic

18

N/A

Label Alignment Length

AL

000 – 999

1/100 inch

19

N/A

Label Width

LW

75 - head width

1/100 inch

15

<STX>KM

No Paper Min (OOS)

TN

0

– 16

.1 Volt DC

11

N/A

No Paper Min Reflective

RN

0

– 16

.1 Volt DC

11

N/A

Print Method

MT

D, T

Direct, Thermal Transfer

1

<STX>KD

Present Adjust

PA

0 – 255

Dots

6

N/A

Present Sensor Enable

PS

Y, N

Enabled, Disabled

3

<STX>KD,

 

 

 

 

 

 

<STX>V

Scalable Cache

SC

0 – 128

4 KB (0 = disabled)

16

<STX>KS

Sensor Type

ST

G, C, R

Gap (Edge), Continuous,

2

<STX>e,

 

 

 

 

Reflective

 

<STX>r,

 

 

 

 

 

 

<STX>KD

Serial Port Configuration

SP

 

A

See details below

7, 8

<STX>KD

SOP Adjust

SA

0 – 255

Dots

5

N/A

Stop Location

SL

H, P, C, T, N

Host, Peel, Cut, Cover, None

20

N/A

TOF Bias

TB

0

– 50

.1 Volt DC

14

N/A

TOF Bias Reflective

RB

0

– 50

.1 Volt DC

14

N/A

TOF Delta

TD

0

– 50

.1 Volt DC

13

N/A

TOF Delta Reflective

RD

0

– 50

.1 Volt DC

13

N/A

TOF Gain

TG

0

– 15

.1 Volt DC

12

N/A

TOF Gain Reflective

RG

0

– 15

.1 Volt DC

12

N/A

Table 5-2: Set Configuration Commands

Configuration Query – This command causes the printer to respond with the current configuration settings. The <STX>Kc response command stream format is sent to the host

30

E-Class DPL Programmer’s Manual

Page 40
Image 40
Datamax E4203 manual STXKcaa1val1aaIvalIaanvalnCR, Set Configuration Commands